Manual

Page12
7MenuStructure
MAINMENU
SETTEMP
USERTIMER
CL
OCK
USERALARM
SLEEPTIMES
MAINTENANCETIMERS
MISCELLANEOUSOPTIONS
ADVANCEDOPTIONS
LOADDEFAULTS
SUBMENU
UserAlarm1
UserAlarm9
SUBMENU
SleepTimer1
SleepTimer9
SUBMENU
SUBMENU
SUBMENU
GeneralService
CabinetService
ReplaceFilter
Ozonator
Custom1
Custom2
Custom3
Custom4
Custom5
KeyClicks
MainDisplay
Panel&PoolLightSync
*2
PanelLightColour
PanelLightIntensity
HeatControl
FiltPeriod*1
FiltTime*1
*1N/A for24Hrcirculationpumpinstallations
*2N/A ifSPVCL notfitted
HighHeatOffset
----
DAYS:[]
1.SLEEPSTART
Page21
7.6.2Disablingasleeptimeperiod
IfyouwanttodisableasleepperiodfollowtheprocedureoutlinedinConfiguringasleeptimeuntilyoureachstep4.
AtthispointusetheUP
andDOWNbuttonstoadjusttheweekdaysettinguntilnodaysareselected(seepicbelow).
PresstheSCROLL buttontosavethenewsettingandreturntothesleeptimesubmenu. Thiswillcompletelydisable
thesleepperiod.
Whenthesleepperiodisdisabledthestarttimeisshownasbelowandthestoptimecannotbeselectedwithinthe
sleepsubmenu.
Whenyoudisableasleepperiodinthismannerthestartandstoptimesarestillretainedandwillberestoredwhen
youenablethesleepperiodbyre-selectingoneormoreweekdays.
7.6.3Plumbingpurge
Afterthesystemresumesfromasleepperioditwillautomaticallyruneachoftheaccessorypumpsone-by-oneand
thentheblowerfor10secondstopurgetheplumbing.
Thispreventsanystagnantwaterfromcollectinginthepipes
ifthepoolisnotusedforanextendedperiodoftime.Whileaplumbingpurgeisinprogress “PURGINGPUMPS,
PLEASEWAIT” willbeshownontheLCDdisplay.
Notes
1. Forcorrectsleepoperationensuretheclockissetcorrectly. Youwillneedtosetitthefirsttimethecontrolleris
powereduporifthecontrollerhasbeenturnedoffforalongperiod.
2. Themaximumpossiblesleeptimeforoneperiodis23hours,59minutes. Thisisachievedwhenthestoptimeis
oneminutebeforethestarttime.Ifthetwotimesareequalthesleepperiodwillhavenoeffect.
3. Itisnormalforthespatorunforalongperiodaftersleeptorecovertemperaturelostovernight.Becauseofthis
itisadvisabletoconfigurethespatowakeupatleastonehourbeforeuseofthespaisdesired.
7.7Maintenancetimers
TheSP1200controllerhasnineprogrammablemaintenancetimersthatwillremindyouwhenregularscheduled
maintenanceisdue.Eachtimercanbeconfiguredtoexpireafter1to255weeksormaybedisabledaltogether
.
Allninetimersaredisabledbydefaultunlessyourspabuilder/installerhassetthem.
Thefirstfourtimershavespecificnamesforspecifictasks,buttheremainingfivearegeneric. Yourspainstallermay
havechosentouseoneormoreofthecustomprogramsformaintenanceitemsnotcoveredbythegenerictimers.
Onceatimerperiodhasexpiredthetouchpadwillinformyouthatmaintenanceisdueintwoways:
1) Whenthespahasnotbeenusedforoveranhourthefirstkeypresswillresultinalongbeepandtextbeing
displayedindicatingwhichtimerhasexpired. YouwillneedtopresstheSCROLL buttononeormoretimestoclear
thismessage.
2) Whennotwithinthemenusystemandafterapproximately10secondsofinactivity,thetouchpadLCDwill
periodicallydisplaytextindicatingwhichtimerhasexpired. Thistextisdisplayedinplaceofthedefaultmain
displaytextanddoesnotinterferewiththenormaltouchpadinterface.
Inbothcases,thetextdisplayedwillbe “MAINT REQD:” alongwiththenameofthemaintenancetimer.