7.7.3ConfiguringAMaintenanceTimer
Followthesestepstomodifythetotalnumberofweeksorthenumberofelapsedweeksforagivenmaintenance
timer:
1)
SelecttheMAINT TIMERSsubmenu.
2) SelectthedesiredmaintenancetimerusingtheUP andDOWNbuttons.
3) PresstheSCROLL buttononcetoviewthemaintenancetimeroptions.
4) PresstheUP buttononcetobegintimerconfiguration. The TotalWeeksfieldbeginstoflash.
5) UsetheUP andDOWNbuttonstoadjusttheselectedfieldasrequired.Holddowneitherbuttonforautomatic
keypressrepeat.
6) PresstheSCROLL buttontoconfirmthecurrentsettingandmovetothenextfield.
7) Repeatsteps5and6tosetthenumberofweeksalreadyelapsed.Generallyyouwillwanttoleavethisfieldat0
-thestartofthetimedperiod.
8) PresstheSCROLL buttononcetoreturntothemaintenancetimersubmenu.
(ESC)
(CFG)
----
008/008WEEKS
5)PresstheSCROLL buttontoconfirm
andmovetothenextfield.
7.7.4DisablingAMaintenanceTimer
Ifyouwanttodisableamaintenancetimerfollowtheprocedureoutlinedaboveuntilyoureachstep5. Atthispoint
presstheDOWNbuttonuntilthe TotalWeeksfieldis0.PresstheSCROLL buttononcetosavethenewsettingand
returntothemaintenancetimeroptionsview. Thiswillcompletelydisablethemaintenancetimer.
Notes:
1) Lowestnumberedtimershavethehighestpriorityandwillbeshownfirstiftwoormoretimersaredueatthesame
time.Clearingthefirstmaintenancetimerwillresultinthecontrollernotifyingyouthatnexthighestprioritytimeris
due.
2) Themaintenancetimerswillnotaccumulatetimewhilethecontrolleristurnedoff.
(CLR)
(ESC)
(CFG)
----
000/008WEEKS
4) PresstheDOWNbuttontoresettheweekcounttozero.
Resettozero
Up
Down
Push4 (Light Adjust)
LIGHTADJUST:
100
36.75
C
O
Page10
6SpaPowerVariableColourLight(SPVCL)
TheSpaPowerV
ariableColourLightiscontrolledviatwotouchpadbuttons-LightLevelandLightEffectMode.If
noSPVCL isfittedthenthebuttonscanstillbeusedtoproducelightingeffectsonthetouchpadasthoughalight
wasfitted.
TheLightLevelbuttonselectstheintensityofthelightandtheLightEffectModebuttonselectsthelightcolourand
effect.
PressingtheUP orDOWNbuttonwhileinhigh,mediumorlowmodewillautomaticallychangetoadjustablemode.
6.1AdjustableLightIntensityMode
IntheadjustablelightintensitymodetheUP andDOWNbuttonsareusedtosetthelightbetween2and100percent
ofmaximumintensity.OnthefirstpressofUP/DOWNtheLCDwilldisplay “LIGHT ADJUST” alongwithabargraph
showingthecurrentsetting.WhileviewingthisdisplayyoumaypresstheUP andDOWNbuttonstoadjustthe
intensityasrequired.Holddowneitherbuttonforautomatickeypressrepeat. Thissettingissavedandwillbe
automaticallyrestorednexttimeyouselecttheadjustablelightintensitymode.
FivepushesoftheLightlevelbuttonselectsthelightintensityasfollows:
2) Pressingthe AirbuttonwhiletheblowerisrunningwillonlycyclethroughtheavailableoptionswhentheLCDis
displayingthecurrentselection. ThisallowsyoutosetthefunctionoftheUP andDOWNbuttonsandtoview
thecurrentBlowersettingwithoutchangingit.
3) PressingeithertheUP orDOWNbuttonwhileinthefull-speedoroscillatingmodewillautomaticallychangethe
SPVSBtoadjustablespeedmode.
4) Iflefton,thisaccessorywillautomaticallyswitchoffafter25minutes.
5) Iftheheaterelementison,switchingontheSPVSBmaycausetheheatertoloadshedandswitchoff.Ifthis
occurstheheaterwillcomebackonapproximately5secondsaftertheSPVSBisturnedoff.
Push2 (Medium)
Push1 (High)
Push3 (Low)
Push4 (Adjust)
Push5 (Off)
LCDDisplays “LIGHT HIGH”,100%lightintensity
LCDDisplays “LIGHT MEDIUM”,66%lightintensity
LCDDisplays “LIGHT LOW”,33%lightintensity
LCDDisplays “LIGHT ADJUST”,adjustablelightintensitymode,
buttonLEDcolourchangeswithsettingwhenupordownbuttons
arepressed.(Green2-32,Orange34-66,Red68-100%)
(See “AdjustableLightIntensityMode” innextsectionformoredetails.
LCDDisplays “LIGHT OFF”,lightoff