ECO-matic Control Panel
System
Control Dial
External Control
Setting
Easy Access
Fuse
Operation
LED
ON / OFF
Switch
LED
Production
Bar Meter
Special Features
System Control
The System Control varies the amount of time the Cell operates during the ltration cycle. The System Control will not vary
the electrical current supplied to the Cell. As an example, if one ltration cycle is set at 5 hours, and the System Control is
set to 80%, then the total amount of time the Cell will operate during the 5-hour cycle will be 4 hours. If the System Control
is set to 60%, the Cell will operate for 3 hours total over the 5-hour ltration cycle.
During the ltration cycle, the Cell will be turned ON and OFF a number of times each hour, unless the System Control is
set at MIN or MAX.
When the System Control is set to MIN, the Cell will be OFF for the duration of the ltration cycle. When the System
Control is set to MAX, the Cell will be ON for the duration of the ltration cycle.
If the Cell is OFF and you wish to check its operation, simply turn the System Control to MAX and the Cell will turn ON.
Once checked, adjust the System Control back to the desired position and after a few minutes the Cell will turn OFF again.