Owner manual

26 11

Things you should be aware of:
 
®
please
read all instructions carefully as
failures caused by incorrect
installation are not covered under
warranty.
 
®
is designed to handle
clean water and should not be used
for any other purpose without specific


®

corrosive or other materials of a

system and void the warranty.
 
will damage the system and void the
warranty.
 
®


®
and pump so that they are

 
electrical devices attractive for

pump is susceptible to insect
infestation you should implement a
suitable pest control plan.
 Limit mains water pressure to
900kPa.
 

®
controller is
recommended to stop foreign matter
entering the unit and damaging it.
 
labelled in accordance with local


requires that all pipework containing
rainwater is marked with green

meter intervals and every outlet that
may deliver rainwater is to be


 

®
unit are protected from
access by pets and/or children.
 
checks must be made by a qualified
electrician and comply with applicable

connections need not be carried out
by a qualified electrician, but should
be done in compliance with applicable
standards.
 

you that this controller and any pump
controlled by it is not to be used by
children or infirm persons and must
not be used as a toy by children.
Type 1 installations. Above ground
tank and pump outside tank.
 
top of the pump and fill the casing
and suction line with water then refit

fitted on the delivery pipe from the

needs to be opened.

pump casing is not fully filled with water,

the case you should repeat the priming

properly this may be a fault in the way

should be slightly higher than the pipe
inlet and this should run up hill to the
pump at a slight but consistent slope so

the pump is primed.
 

clear trapped air. Make sure an outlet

dispelled. Make sure the mains water is
turned off until the pump is fully primed.
IMPORTANT

prime.

switch.
Type 2 and 3 installations.
Submersible pumps inside tank.

water the pump will self prime and push
air out of the taps and appliances that are

without causing damage it is important
that:
 
system are turned on
 

is cleared from the line.
