Owner manual
9 
OZOMATIC
®
 INSTALLATION FOR SPAS AND POOLS 
WITH HIGH BACK-PRESSURE 
For in-ground spas where installation of a mini-footwell Injector is not possible, or where back-pressure 
is high it is possible to install a High Efficiency Injector in a by-pass around the sand filter. This type of 
installation uses the pressure developed across the filter to help drive the injector. 
A 3-way valve is plumbed between the pump and filter. Reducing bushed/barbed connectors are fitted to 
the  valve  port  that  will  feed  the  High  Efficiency  Injector,  20mm  (3/4”)  flexible  tubing  can  be  used  to 
connect into  the High Efficiency Injector  inlet. A Tee  - piece is plumbed  after the filter  with one of its 
ports reduced/barbed to allow fitting of the 20mm (3/4”) flexible tubing from the High Efficiency Injector 
outlet. Ensure that water flow is in the direction of the arrow on the High Efficiency Injector. 
The clear ozone hose should be connected to the injector as shown in the diagram. Ensure that the non-
return valve is fitted in the right direction. 
Before starting the pump, close the 3-way valve port to the injector. This means that the port to the filter 
will be open. 
Start  the  pump  and  begin  to  open  the  valve  port  to  the  injector.  Keep  opening  valve  until  suction  is 
achieved. Using the optional gas flow meter, adjust the suction until the correct flow is achieved (8-10 for 
MOG 20 and MOG 60, 16-20 for MOG 120). 
IMPORTANT - The clear hose comes complete with a non-return valve. Make sure that this valve 
is around the right way so that air can be drawn through the ozone unit. If the Ozomatic is to be 
installed  below  water  level  then  the  clear  hose  must  be  looped  above  the  highest  possible  point; 
otherwise the water could drain out of the spa through the ozone unit causing damage. Warranty is 
void if water damage is apparent. Refer to warranty card for detailed conditions. 
A
N EXAMPLE OF THIS SITUATION IS RETRO-FITTING OF IN-GROUND SPAS AND POOLS WITH FOUNTAINS 
OR WATERFALLS 
BY-PASS INJECTION FOR SYSTEM WITH BACK-PRESSURE IN RETURN LINES 