Owner manual
8 
OZOMATIC
®
INSTALLATION FOR ABOVE GROUND POOLS 
USING THE BY-PASS INJECTOR 
MODELS MOG 60 AND MOG 120 
(ALSO MOG 20 FOR COURTYARD POOLS AND SPAS REQUIRING A BY- PASS INJECTOR) 
On systems where the back-pressure is likely to be high, such as below  ground spas  or pools with high head 
features (e.g. high waterfalls), a different injection approach may be needed. See “Ozomatic installation for spas 
and pools with high back-pressure”. 
Your Ozomatic
®
 and injector are purchased separately. Ensure that you have selected the proper injector. The 
high efficiency injector used is the most efficient injector available. 
The by-pass injector should be plumbed into the return line after all other accessories. The clear hose should be 
connected to the barb on the injector (refer diagram). The amount of air flow through the Ozomatic should be 
adjusted by turning the ball valve on the injector. By using the optional flow gauge and attaching it to the end of 
the clear hose a flow of approximately 8-10 for models MOG 20 and MOG 60 and 16-20 for MOG 120 on the 
gauge indicates optimum ozone production. 
On systems where the back-pressure from the pool is so great that a suction cannot be created no matter how 
much the ball valve is closed down then either the pool pump should be reduced in size or the impeller changed 
to reduce the water flow. This situation usually exists when the pump has been replaced with a larger one on 
existing pool/spas. 
IMPORTANT  –  The  clear  hose  comes  complete  with  a  non-return  valve.  Make  sure  that  this  valve  is 
around the right way so that air can be drawn through the ozone unit. If the Ozomatic is to be installed 
below water level then the clear hose must be looped above the highest possible point; otherwise the water 
could drain out of the spa through the ozone unit causing damage. Warranty is void if water damage is 
apparent. Refer to warranty card for detailed conditions. 
OZONE AIR LINE - MUST BE DOUBLE LOOPED AND CONNECTED ABOVE WATER LEVEL 
BY-PASS INJECTION FOR ABOVE GROUND 