Owner manual
6 
VENTURI AIR SUCTION 
The Venturi air suction method is accomplished by connecting the Ozomatic to the Venturi air line of the spa. 
This system is easy where access  to the air lines is available  but on existing spas might not be  possible. The 
main drawback with this system is that the ozone is only drawn into the spa when the air controls are closed. 
When they are opened, the amount of ozone drawn into the spa decreases dramatically. This system is the least 
efficient injection method. 
1. 
2. 
3.  
4. 
5. 
VENTURI AIR SUCTION SYSTEM 
OZONE AIR LINE 
- MUST BE DOUBLE LOOPED AND 
CONNECTED ABOVE WATER LEVEL 
Locate the Ozomatic Unit outside or underneath the spa skirting so that it is close to the spa air line and the 
operating light can be seen. 
Install the Tee and hose barb. 
Form a double loop of ozone hose and secure it above the water level. 
Note: There is a non-return valve on the ozone hose. Blow into the hose to ensure ozone will be able to 
flow in the correct direction. The non-return valve is designed to operate under pressure and it is possible 
for  water to  seep  past it  when no  pressure is applied; hence the loop is an extra safeguard to  stop  water 
entering the Ozomatic. 
Close the air controls and turn the pump on. Ensure that a bubble mist is entering the spa from at least one 
of the jets. Place a finger over the end of the Ozone hose and ensure that the air entering the spa is being 
drawn through the hose. Connect the hose to the Ozomatic. 
Note: The air control must be kept closed when the spa is operating during its normal filter cycle. If it is 
not,  air  will  be  drawn  in  through  the  air  control  and  you  will  not  produce  any  ozone,  nor  will  you  be 
ozonating the spa water. 
Plug the Ozomatic into the power outlet (that controls the pump) and ensure that the operating light is on. 