Discharge Piping -Thepumpoutletis2”BSPfemaleand2”orlargerpolythenepipingorequivalentshouldbeused,
particularlyifsprinkleristobeoperated.
Operation
Whenrstinstalledthepumpmustbelledwithwaterattheprimingholeadjacenttopumpoutlet.Aweightedapvalve
onthesuctioninletretainstheliquidwithinthepumpforsubsequentoperation.
Asthispumphasexcellentselfprimingcharacteristics,thereisnoneedtotafootvalveorllthesuctionpipe.
Anautomaticoatswitchmaybewiredintothecontactorcoiltooperatethepump.
Maintenance
1.Monthlygreasethesealareaatthenipple(seeexplodedview-Item2)locatedintheyoke(Item7)joiningpump
andmotor.UseBP “ENERGREASE”multipurposeLS2orequivalent.
2.Regularushingofthepumpwithcleanwaterisgoodpracticewhenpumpingdairyorpiggerymanure,andwill
preventbuildupandtheneedtounclogfrequently.
3.Ifthepumphasbeenidleforalongperiod,removetheinspectioncover.(Item18locatedbelowthepumpinlet),
andensurepumpimpellercanrotatefreely.
4.Tocleananyblockages,thelargeinspectionholeprovidesexcellentaccesstopumpimpellerareaforcleaning.
Periodiccleaningoutofthepumpisgoodpractice.
Impeller Clearance Adjustment
TheMukmovapumphasanopenfaceimpeller(seetheexplodedview–Item4).Asthispumpisusedtopumpmanure
and“trash”,theimpellerwillwearovertime.
Theoptimalperformanceofthepumpismaintainedbyclosetoftheinspectioncover(Item18)tothefrontofthe
impeller.Thisclosetismaintainedoverthelifeofthepumpbyperiodicremovaloftheimpellershims(Item17).
Whenthepumpismanufacturedthecorrectnumberofshimswillbeinsertedforpeakperformance.Asthis
performancedeclinesovertime,impellershimswillneedtoberemovedtooptimisetheperformance.
Ifallshimsareremovedandperformancecontinuestodecline,itistimetoreplacetheimpeller.
Spare Parts
Shouldanypartsberequired,besuretoquoteModel and/or Buildnumberfromthenameplateonthepump.
NOTE: The use of suction piping smaller than 2
1
/
2
” I.D. will result in decreased pump performance. When
pumping dairy or piggery slurry, no inlet strainer should be tted to the end of the suction hose as this may
easily be blocked.
The pump is capable of pumping up to 3/4” dia. solids in suspension, however pumping stones or hard
solids of any size for extended periods will shorten the pump’s life. A coarse screen should be installed
at the entrance to the collection pit to prevent large items including rocks, sticks and some straw from
entering.