User Manual
MUKMOVA
MANURE & “TRASH” PUMP
INSTALLATION AND OPERATING INSTRUCTIONS
Please pass these instructions on to the operator of this equipment
Prior to using this pump you must ensure that:
• Thepumpisinstalledinasafeanddryenvironment
• Thepumpenclosurehasadequatedrainageintheeventofleakage
• Anytransportplugsareremoved
• Thepipe-workiscorrectlysealedandsupported
• Thepumpisprimedcorrectly
• Thepowersupplyiscorrectlyconnected
• Allstepshavebeentakenforsafeoperation
AppropriatedetailsforalloftheseitemsarecontainedinthefollowingInstallationandOperatingInstructions.Read
theseintheirentiretybeforeswitchingonthispump.IfyouareuncertainastoanyoftheseInstallationandOperating
InstructionspleasecontactyourDaveydealerortheappropriateDaveyofceaslistedonthebackofthisdocument.
Location
Thepumpmustbeprotectedfromtheweather.Ifitistobelocatedoutside,aweatherproofsheltermustbeputoverthe
pumpandmotor.Thissheltermusthaveventilationtoallowthemotortodrawinairforcooling,andadequatespace,so
asnottorestricttheowofairtothemotor.Thesheltershouldbereadilyremovableforaccesstothepumpatalater
date.Locatethepumpascloseaspossibletotheliquidtobepumped.Provisionismadeinthebaseofthepumpfor
boltingdown,anditisrecommendedthatthepumpbepermanentlysecured,particularlyfordairyandpiggeryuse.
Installation
Power
NOMINAL MAXIMUM * LOCKED
POWER SUPPLY PHASE CYCLES RATED CURRENT ROTOR CURRENT
230V +10% 1 50Hz 11Amps 68Amps
480V+10% 1 50Hz 5.5Amps 38Amps
415V +6% 3 50Hz 5.1Amps 24Amps
*Maximumratedcurrentisthemaximumforthemotor,andishigherthanthatrequiredwhenpumpingcleanwater-
thisistoallowamotorpowerreservewhenpumpingefuent.
WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or
property damage.
In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not to be used by children or inrm
persons and must not be used as a toy by children.