Manual
9
Function
Description
Selector
Switch
Position
Functions and Instructions
Set Clock 1
Set the current time on the digital clock.
Select the Set Clock position on the selector switch to enable the time of day to
be input. A number ‘1’ will appear at the left of the screen.
(a)Thedisplaywillashonandoffaslongastheselectorswitchremainsatthis
position. Use the up ▲ and down ▼ buttons to reach
the desired times. Hold the buttons down for fast increments.
Set Timer 1 – ON 2
Setthestarttimefortherstruntimesequence.
Select the Set Timer 1 – ON position on the selector switch. A number ‘2’ will
appear at the left of the screen.
Thistimeisfactorypre-setto6am.Proceedasper(a)inthe‘SetClock’
instruction to change time.
To disable this timer, move up or down to 11.59PM. Press the UP button one
more time to turn OFF. NOTE: This step will also disable the time for ‘Set Timer
1 – OFF’.
Set Timer 1 – OFF 3
Setthecompletiontimeoftherstruntimesequence.
Select the Set Timer 1 – OFF position on the selector switch. A number ‘3’ will
appear at the left of the screen.
Thistimeisfactorypre-setto8am.Proceedasper(a)inthe‘SetClock’
instruction to change time.
Set Timer 2 – ON 4
Set the start time for the second run time sequence.
Select the Set Timer 2 – ON position on the selector switch. A number ‘4’ will
appear at the left of the screen.
Thistimeisfactorypre-setto5pm.Proceedasper(a)inthe‘SetClock’
instruction to change time.
To disable this timer please refer to selector switch position 2 above.
Set Timer 2 – OFF 5
Set the completion time for the second run time sequence.
Select the Set Timer 2 – OFF position on the selector switch. A number ‘5’ will
appear at the left of the screen.
Thistimeisfactorypre-setto11pm.Proceedasper(a)inthe‘SetClock’
instruction to change time.
To disable this timer please refer to selector switch position 4 above.
Automatic ON 6
Filtration system switches on and off automatically according to your set times.
Select the Automatic ON position on the selector switch. A number ‘6’ will
appear at the left of the screen.
Manual ON 7
OverridestheautomatictimeclocksettingsandswitchesltrationsystemON.
Select the Manual ON position on the selector switch. A number ‘7’ will appear
at the left of the screen.
NOTE: Chlorination will be constant until turned OFF or back to Automatic ON.
Over chlorination may occur if left for long durations.
OFF 8
OverridestheautomatictimeclocksettingsandswitchesltrationsystemOFF.
Select the OFF position on the selector switch. A number ‘8’ will appear at the
left of the screen.
NOTE: Chlorination / sanitisation will cease. Not recommended for long
durations.