Manual
5
•Page4•
CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY:
ThePowerSupplyisttedwithaexibleleadterminatedwithbrassconnectors.Thesemustbecorrectly
ttedtotheconnectionsontheinsideoftheCellHead.Topreventincorrectconnectionthettingshavebeen
colour coded.
ESR Black to Black & White to White
ESC /
ESCpH
Either Black Terminal
The Blue Gas Sensor connector should be pushed onto the thread of the small bolt. The power outlet on the
bottom of the Power Supply is dedicated to the POOL PUMP ONLY.
Important:TheCellmustbeinstalledsothatthewaterowsthroughtheCellHousingviatheCellheadend
in accordance with the arrow on the cell housing. This is to ensure correct operation of the gas sensor.
PRE - START UP PROCEDURE:
Before operating your ChloroMatic® please ensure the following items have been added to your pool:
• SALT-Loadsaltintothepoolatthefollowingrates:
•AllChloroMaticModels–Around45-60kgper10,000litres(4500-6000ppm)
Connect manual vacuum system and slowly vacuum until salt dispersal is complete. Place vacuum head into
deepest end of pool and allow vacuum to continue for a further 2 or 3 hours. Salt should now be completely
mixed. Never add salt directly into skimmer box.
• CHLORINE-Foranewpoolinstallationthathasnotbeenchlorinated,addsufcientChlorine(liquidor
granular) to achieve a reading of 3 ppm (with a suitable test kit), or run the chlorinator system continuously
for at least 24 hours or until a reading of 3 ppm is reached.
• STABILISER-Itisessentialthatpoolstabiliserbeaddedandmaintainedattherateof30-50ppmatall
times. Do not exceed 100 ppm.
(Refer Day to Day Operation page 12 for further information).
OPERATION OF YOUR ChloroMatic
®
SYSTEM:
Cell OutputonthedigitalLEDdisplayisexpressedasapercentage.TheDisplaywilluctuatearound100
whenproducingsanitiser-unlessinWinterMode,inwhichcasetheDisplaywilluctuatearound85.(Refer
WinterModepage8).TheUnitisttedwithanelectroniccontrolandwarningsystem.Thisregulatesthe
output of the Unit to the preset maximum. The warning system consists of two Operation LED’s that will glow
Green, or Red to indicate possible faults with the Unit or damaging operating conditions.
Do not use a double adaptor to connect more than one pump - it can cause overload to the system
and could void your warranty. *Does not relate to MCS50C.