Owner manual
7
Weather Protection
It is recommended that the pump is protected from the weather.
Power Connection
DaveyMaxiFlowpumpsaresuitableforconnectiontoanominal240volt50Hzpowersupply
andareequippedwithaexleadand3pinplugorAMPplugtoallowconnectabilitytoa
DaveySpacontroller.Ifapoweroutletisnotavailablewithin3metresofthepump,a3pin
powerpointinasafe,dryplace,mayneedtobeprovidedbyanelectrician.Extensioncords
areunsafearoundpoolsorspas-andshouldbeavoided.Ifthesupplycordofthisproductis
damageditmustbereplacedbythedealerormanufacturer,withgenuineDaveyspares.All
pumpsmustbesuppliedthroughaResidualCurrentDevice(operatingcurrent<30mA).This
isnormallyttedinthesupplytothecontrolsystem.
Pipe Connection
TheMaxiFlowpumpsarenon-selfpriming;thismeansthatthepumpmustbemountedbelow
the minimum water line. This MaxiFlow pump is designed to be operated with 50mm diameter
pipe-work.Togetbestperformanceensurethatthereareaminimumnumberofbendsin
thepipe-work.Itispreferabletouseexiblepipinginordertogetthebestperformance.The
plumbingshouldhavenorestrictionsthatwillimpedeorrestrictthewaterow.
ThepumpshouldbermlysecuredtothebaseoftheSpa,preferablyitshouldbemounted
on some resilient material to reduce any possible vibration. When installing any pump ensure
thatithasadequateventilation,whichismostimportant.Lackofadequateventilationwill
causethepumptoover-heatandcancausedamagetothewindings,thebasicinsulation,the
bearinglubrication,andthestartcapacitorandcouldcausefrequenttrippingofthethermal
shutdown switch.
If the pump and lter are located below pool water level, it is necessary
to t isolating valves in the pipe between the pump and the skimmer box
or suction inlet and in the return pipe from the lter to the pool.
Warning! Ensure that an electrical isolation switch is located with easy
access so that the pump can be switched off in an emergency.
CAUTION:
In the interest of safety, we advise that all brands and types of spa pool pumps
must be installed in accordance with AS3000 wiring rules or equivalent
Davey Water Products recommends that all installations are tted with
earth leakage or residual current protection devices.
This pump is not to be used by children or inrm persons and must not
be used as a toy by children.