Priming and Operation
ThePresscontrolmodulettedtoyoursystemisprovidedwithapushbutton
“Prime”button.Thisbuttonisusedduringinitialprimingofthepumpandalsoacts
asaresetbuttonifthePresscontrolswitchesoutinpumpprotectionmode.
1. Removeprimingplugandllcasingandsuction
line(onoodedsuction,simplyopengatevalveto
pump).Whenfull,replaceprimingplug.
2. Ensure outlet nearest
to pump is open.
3. Ensureallvalvesinsuctionlineareopen.
4.Switchonpower-Thestatusindicatorlightwillbeilluminated
greenandthepumpwillrun.Afullowofwatershouldbe
dischargedfromtheopentap.
5.Ifthepumpstopswiththetapopenseetroubleshootingchecklist.
6. Closetheopenoutletortapandthepumpshouldstopafterafewseconds(the
statusindicatorlightshouldbeilluminatedred(constant).Ifnot,consultthe
troubleshootingchecklist.
To Reset if Pump switches out in Pump Protection Mode
1. Makesurepumpisprimed.
2. Opentap,pushprimebutton.
3. Closetapandpumpwillstop.
Power Connection
Connectleadtopowersupplydesignatedonpumplabel.Donotuselong
extensionleadsastheycausesubstantialvoltagedrop,poorpumpperformance
andmaycausemotoroverload.
Electrical Power Surge Protection
Anelectricalpowersurgeorspikecantravelonthesupplylinesandcause
seriousdamagetoyourelectricalequipment.ThePresscontrolttedtothispump
hasametaloxidevaristor(MOV)ttedtohelpprotectit’scircuit.ThisMOVis
a“sacricial”device,meaningthatiteffectivelyisgraduallydamagedeverytime
ittakesasurge.TheMOVisnotalightningarrestorandmaynotprotectthe
Presscontroliflightningoraverypowerfulsurgehitsthepumpunit.
Iftheinstallationissubjecttoelectricalpowersurgesorlightningwestrongly
recommendtheuseofsuitableadditionalsurgeprotectiondevicesonALLelectrical
equipment.
The Presscontrol tted to this pump has a status indicator light mounted
on its front panel. This light will be illuminated whenever the Presscontrol
senses that there is electrical power available. The light will only work
when unit is connected to the correct electrical supply.
The electrical connections and checks must be made by a qualied
electrician and comply with applicable local standards.
NOTE: For protection, the Davey pump motors are tted with an automatic
reset thermal overload, constant tripping of this overload indicates a
problem e.g. low voltage at pump, excessive temperature (above 50°C) in
pump enclosure.