WARNING: When servicing or attending pump, always ensure power
is switched off and lead unplugged. Electrical connections should be
serviced only by qualied persons. If the electrical supply lead of this
pressure system is damaged, it must be replaced.
2 11
Prior to using this pump you must ensure that:
• Thepumpisinstalledinasafeanddryenvironment
• Thepumpenclosurehasadequatedrainageintheeventofleakage
• Anytransportplugsareremoved
• Thepipe-workiscorrectlysealedandsupported
• Thepumpisprimedcorrectly
• Thepowersupplyiscorrectlyconnected
• Allstepshavebeentakenforsafeoperation
AppropriatedetailsforalloftheseitemsarecontainedinthefollowingInstallation
andOperatingInstructions.Readtheseintheirentiretybeforeswitchingonthis
pump.IfyouareuncertainastoanyoftheseInstallationandOperatingInstructions
pleasecontactyourDaveydealerortheappropriateDaveyofceaslistedonthe
backofthisdocument.
Congratulationsonyourpurchaseofahighquality,AustralianbuiltDaveypressure
system.Allcomponentshavebeendesignedandmanufacturedtogivetroublefree,
reliableoperation.
Yournewpressuresystemincorporates‘Presscontrol’,electronicowcontrollerthat
enablestheuseofahighlyefcientpumpdesignandoffersthefollowingbenets:–
1. Enablesthepumptodeliveraconstantowofwaterparticularlyatlowow
rates–reducingtheinconvenienceofpressurevariationinshowersetc.
2. Providesautomatic“cut-out”protectionshouldthepumprunoutofwater.
3. Provideswarningindicationsforcriticalsystemfaults.
1. DischargeOutlet(1”BSPM)
2. PresscontrolModule
3. SuctionInlet(1
1
/
4
”BSPF)
4. PumpBody
5. Motor
6. RotaryCoupling
7. Priming Plug
NOTE:
For protection, the Davey
®
pump motor is tted with an automatic “over
temperature” cut-out. Constant tripping of this overload device indicates a
problem e.g. low voltage at pump, excessive ambient temperature (above
50°C) in pump enclosure.
Care should also be taken when servicing or disassembling pump to avoid
possible injury from pressurised water. Unplug pump, relieve pressure by
opening a tap on the discharge side of the pump and allow any hot water in
the pump to cool before attempting to dismantle.
During servicing, use only approved, non-petrochemical based oring and
gasket lubrication. If unsure, consult your Davey Dealer for advice.
WARNING: Do not use hydrocarbon based or hydrocarbon propelled
sprays around the electrical components of this pump.
Before installing your new pump, please read all instructions carefully as
failures caused by incorrect installation or operation are not covered by the
guarantee. Your Davey pressure system is designed to handle clean water.
The system should not be used for any other purpose without specic
referral to Davey. The use of the system to pump ammable, corrosive and
other materials of a hazardous nature is specically excluded.
NOTE:Priortoinstallationremovetheredtransportplugsfromthesuctionand/ordischarge.
In accordance with AS 3350.2.41 we are obliged to inform you that this
pump is not to be used by children or inrm persons and must not be used
as a toy by children.