Manual

• Page 9
SPECIFICATIONS
D = Clearance to remove cartridge
TECHNICAL DATA
Max Max Filtration
Flow Max Operating Area Filtration
Rate 4 Hour 6 Hour Operating Temp (sq metres) Area
Model (lpm) Turnover Turnover Pressure (kPa) (°C) (sq feet)
Q2201MN 230 55,000 83,000 280 45 4.75 50
Q2202MN 325 78,000 117,000 280 45 7.0 75
Q2203MN 400 96,000 144,000 280 45 9.5 100
Q2204MN 490 117,000 176,000 280 45 14.25 150
DIMENSIONS (mm)
Model A B C D
Q2201MN 410 60 540 835
Q2202MN 410 60 540 835
Q2203MN 410 60 635 1200
Q2204MN 410 60 820 1555
All dimensions in mm unless otherwise stated.