Instruction Manual
6 
Technical Data: 
Model 
MCU / LCU 
Power (V) 
220-240 
Power Outlets 
2 
Outlet rating (A) 
10A Total 
Power Lead length (m) 
1.9 
Electrical Approval 
NSW23093 
IP 
53 
Dimensions: 
(mm) 
Height 
Width 
Depth 
Mounting 
Holes (Horiz) 
Mounting 
Holes 
(Vert) 
Mounting 
Holes Diam 
MCU 
208 
119 
88 
99 
188 
5 
LCU 
124 
99 
104 
Installing the Master Control Unit (MCU): 
1.  When installing your MCU it is easier to program the network prior to mounting. 
Simply plug in to any power outlet to activate the unit and begin programming. 
Refer to the section titled “Programming the MCU”. 
2.  Mount the MCU in a location that is greater than 3.5 meters from the pool zone 
and less than 1.5 meters from a power supply socket. Make sure the unit is 
within range of other units before mounting. 
3.  Plug the appliances to be controlled, into the outlets in the base of the MCU. 
WARNING: The total current of the MCU must not exceed 10 Amp. The unit 
must be installed in the upright position. 
4.  Plug the mains input lead into the power outlet 240V supply. 
5.  Switch on the power outlet and the 2 override switches on the MCU unit 
(mechanical rocker switch above the outlets). 