3” and 4” Floodfighter™ Pumps Installation and Operating Instructions These Instructions and the accompanying engine manufacturer’s instructions must be delivered with the pump to the operator. Please pass these instructions on to the operator of this equipment.
READ ALL INSTRUCTIONS BEFORE OPERATING PUMP NOTE: • Your Davey pump is fitted with a four stroke engine WHICH REQUIRES OIL IN THE SUMP. • Petrol engines require UNLEADED petrol in the fuel tank. • Read ALL instructions to avoid equipment failure which may not be covered by guarantee. • Fill sump with oil and pump with water before starting. YANMAR diesel engines do not have low oil protection. Check oil levels and maintain oil quality regularly.
PUMP LOCATION: For most efficient operation, site the pump as close to the water as practical. It is essential for the correct function of the engine that it be located on a horizontal surface. If allowed to run at an inclination, the oil lubrication system of the engine may not operate correctly. Subsequent engine failure would not be covered by the manufacturer’s guarantee.
PUMP OPERATION: High performance can be obtained from these pumps if the engine speed is increased, however, we do not recommend the pumps be operated over 3600rpm for extended periods, as this may overload the engine and reduce its working life. Operating the engine at full throttle for extended periods will shorten engine life and may result in premature failure. For operations such as irrigation or dam and tank filling, the throttle should be closed to around 3/4 maximum.
Air Cleaners In a fire emergency you need every ounce of performance from your pump unit to be available, and poorly maintained air cleaners won’t help you. Adequate clean air flowing into the engine at the right speed and temperature is vital for efficient combustion: • Follow the engine manufacturers’ schedule and instructions for the correct maintenance of the air cleaner. • Ensure your engine has access to ample clean fresh air.
STORAGE OF UNIT: The pump unit should be drained of water and normal engine storage procedure should be followed. (Run unit until fuel is exhausted, drain and fill sump with fresh oil.) The unit should be stored in a dry place. Before starting pump after storage it should be checked to make sure that it is free to rotate by pulling Engine Starter with ignition off. REMOVAL OF IMPELLER: Pump impeller is screwed clockwise onto the engine shaft.
Davey® Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty periods beginning from the date of original purchase due to faulty materials or manufacture, Davey will at our option repair or replace it for you free of charge, subject to the conditions below.
AUSTRALIA NEW ZEALAND Davey Support Centre 6 Lakeview Drive, Scoresby, Australia 3179 Ph: 1300 367 866 Fax: 1300 369 119 Website: davey.com.au Davey Support Centre 7 Rockridge Avenue, Penrose, Auckland 1061 Ph: 0800 654 333 Fax: 09 527 7654 Website: daveynz.co.nz Davey Water Products Pty Ltd Member of the GUD Group ABN 18 066 327 517 ® Davey is a registered trademark of Davey Water Products Pty Ltd. ™ Floodfighter is a trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2013.