User Manual
124
Dave Smith Instruments
Global Settings
5. MIDI Clock Cable: MIDI Port, USB—Sets the port, MIDI or USB, by
which MIDI clocks are received.
6. MIDI Param Send: Off, CC, NRPN—Changes to the values of front
panel controls are transmitted via MIDI as Non-registered Parameter
Number (NRPN) controllers or as Continuous Controllers (CC). Trans-
mission of parameters can also be turned off. See “Appendix E: MIDI
Implementation” on page 140.
NRPNs are the preferred method of parameter transmission, since they cover
the complete range of all parameters, while CCs are limited to a range of 128.
7. MIDI Param Receive: Off, CC, NRPN—Sets the method by which
parameter changes are received via MIDI. As with transmission, NRPNs
are the preferred method.
8. MIDI Control Enable: Off, On—When On, the synth will respond to
MIDI controllers, including Pitch Wheel, Mod Wheel, Pedal, Breath,
Volume, and Expression.
9. MIDI Program Enable: Off, On—When On, the synth will respond
to received MIDI Program Change and other SysEx messages, and will
transmit them (when prompted) to the MIDI Out.
10. MIDI Sysex Cable: None, MIDI Port, USB—Sets the port, MIDI or
USB, by which System Exclusive data will be transmitted and received.
11. MIDI Out Select: Off, MIDI, USB, MIDI+USB—Sets the port by which
MIDI data will be transmitted.
12. Multi Mode: On, Off—Multi Mode allows separate MIDI control of
voices 1-4 and voices 5-8 when in 8-voice mode and 1-8 and 9-16 when
in 16-voice mode. This enables independent, bi-timbral control of the
Prophet X.
When Multi Mode is on, the Prophet X responds to MIDI data on two
consecutive MIDI channels — the base channel (selected in the Global
menu) and the next highest channel. In 8-voice mode, the base chan-
nel controls voices 1-4 and the other channel controls voices 5-8. In