Service manual
BODY
ElECTRICAL
Thermometer
and
fuel
meter
Condition
Both
thermometer
and
fuel
meter
do
not
operate
Both
thentlometer
and
fuel
meter
indicate
inaccurately
ThennometeJ
Thermometer
does
not
operate
Pointer
indicates
maximum
temperature
Thermometer
does
not
operate
accurately
Probable
cause
Blown
off
fuse
or
improper
connection
Defective
voltage
regulator
Damaged
fused
or
open
contact
Defective
voltage
regulator
Broken
heat
wire
seized
contact
and
or
improper
grounding
Improper
cable
contact
Defective
thermal
transmitter
Defective
thermometer
Defective
thermal
transmitter
Defective
thermometer
Defective
thermometer
Defective
thermal
transmitter
BE
23
Corrective
action
Check
fuse
for
fusing
and
improper
contact
Replace
after
correcting
cause
if
fused
Correct
contact
Replace
In
this
case
meter
operates
excessively
Replace
In this
case
meter
operates
slightly
Check
cable
for
improper
contact
and
repair
if
required
Replace
thermal
transmitter
if
pointer
deflects when
thermaltransmitter
yellow
white
cable
is
grounded
Replace
thermometer
if
pointer
does
not
deflect
when
thermaltransmitter
yellow
white cable
is
grounded
Pointer
moves
to low
limit
when
ignition
switch
is
turned
off
In
this
case
replace
thermal
transmitter
Pointer
indicates
maximum
temperature
even
after
ignition
switch
is
turned
off
In this
case
replace
thermometer
Thermometer
is
seIViceable
when
a
40
n
resistance
is
applied
to
thermal
transmitter
yellow
wihite
cable
cable
is
grounded
and
thermometer
indicates
ap
proximately
800C
I
760F
If
thermometer
is
normal
through
the
above
inspection
Replace
thermaltransmitter