User Manual
3: Operation
3-24 RT7000-MSOP
TransAdapt The RT7000 can be on a fixed channel or in scan mode. On a fixed channel,
TransAdapt operates the same as Selcall. In scan mode, TransAdapt locates
the first usable frequency, not the best.
1. Turn the FUNCTION knob until the TA icon flashes.
2. Press STATUS to turn the option ON.
3. Press SCAN.
4. Press CALL/SEND to initiate the call.
5. Enter the code of the transceiver to call (001 to 255). A call to all
channels (Allcall) is code 000.
6. Press CALL/SEND again. The RT7000 is now under full control of the
TransAdapt circuit.
The RT7000 starts transmission on each of the ten channels until it is
synchronized with the station called.
Display: TA LINK
If the call is unsuccessful, calling discontinues and NO LINK is briefly
displayed.
7. To break the connection, press SCAN.
8. To stop the call before connecting, press CALL/SEND.
Activating the Noise Blanker
The Noise Blanker option (7000NB) eliminates impulse-type interference in
high-noise environments.
1. Turn the FUNCTION knob until the NB icon flashes.
2. Press STATUS to turn the option ON.
Activating Encryption
This Encryption option (7000ENCR) provides high-level security.
1. Turn the FUNCTION knob until the ENCR icon flashes.
2. Press STATUS to toggle between 1 and OFF. The 1 position turns the
7000ENCR on.
For more detailed information on this security option, refer to the 7000-Series
High-Level Encryption operator manual (7000ENCR-MSOP).