User Manual
3: Operation
RT7000-MSOP 3-15
(18) LQA EXCNG For requesting that a calling or called station exchange
a measurement of the link quality received on the other
end. Enter 1 for OFF (no request) and 2 for ON (yes
request), or use the arrows to toggle between OFF and
ON.
(19) LQA DECAY For entering the time period in which an LQA memory
cell linearly decays from a state of perfect (30) to a
state of dead (0). Selectable in periods of 0, 1, 2, 4 or 8
hours.
(20) BER THRSD For entering the acceptable bit error rate threshold (00-
48) for received ALE words. A threshold of 00 allows
for no errors, while a threshold of 48 is the maximum
amount of allowable errors. The factory default is set to
48 allowable errors.
(21) GOLAY THD For controlling the error correcting capability threshold
(0-4). A value of 0 allows for no corrections while a
value of 4 is the maximum amount of corrections
allowable. The factory default is set to 3 allowable
errors.
(22) ERR THRSD For controlling the number of errors allowed before a
word is rejected (0-4). A value of 0 allows for no errors
while a value of 4 is the maximum amount of errors
allowable. The factory default is set to 3 allowable
errors.
(23) MESSG OUT For assigning a number to an outgoing message (from 0
to 9). Enter a new assigned number or an existing num-
ber to review or change. To enter a new or different
message, use (24) NEW MESSG.
(24) NEW MESSG For creating a new outgoing message for the number
assigned in (23) MESSG OUT. Any existing message
is briefly displayed. Use the alpha characters on the
keypad to create a new message up to 90 characters.
(25) MESSG IN For selecting an incoming message for review (from 0
to 9). Messages are deleted when a tenth message is
received.
(26) HANDSHAKE For setting the message exchange compatibility with
other radios. Enter 1 for NO Tx, or 2 for NO Rx.