User Manual

3: Operation
RT7000-MSOP 3-13
ALE Submenu
Described
To access ALE functions enter ALPHA 17 from the Alpha menu. You can
move through the ALE menu in one of two ways:
By pressing the desired function number and then E, or
By using the arrow buttons to scroll through the menu to the function and
pressing E
For information on placing an ALE call,
refer to "Placing an ALE Call" on
page 3-21.
For detailed operating instructions, refer to the 7000ALE Radio
Control Program operator manual (7000ALE-MSOP).
(1) SCAN RATE For selecting the rate at which scanning proceeds. The
arrow buttons toggle between 2 and 5 channels per sec-
ond. The number to the left of the scan rate refers to
option 1 or option 2. Two seconds per channel is option
1 and 5 seconds per channel is option 2.
(2) SCAN GRP For selecting an ALE scan group (from 0 to 9). This
becomes the specified scan group when using (3)
TUNE GRP and (9) MOD GRP.
(3) TUNE GRP For automatically tuning an ALE scan group (from 0 to
9). This tunes all the channels in that scan group.
(4) Rx SELCT For selecting a receive type: 1 for normal ALE receive/
transmit (Rx/Tx); 2 for receive only (Rx ONLY); or 3
for channel setup (CH Rx/Tx) of the RC2 software.
(5) SELF ADRS For selecting an address number to review, change, or
add for this station (from 00 to 19). To enter a new self
address, enter the number. To change an existing
address, scroll to the number and enter a new one.
(6) SELF NAME For entering a new self address name for the address
number selected in (5) SELF ADRS. Any existing
address name is briefly displayed. Use the alpha char-
acters on the keypad to enter from 3 to 15 characters
(no spaces or punctuation). To delete a name enter three
periods (...).
30 NET OTHER (network other)
31 SET TO
32 GET LQA
33 EXIT MENU
Table 3-2. ALE Submenu
ALE
Function
Description