User's Manual

Function Description
Scan
Sets scan mode to On, Priority, or Off.
Position A: Scan, Priority scan, or off
Position B: Scan, Priority scan, or off
Position C: All scan modes off
Monitor
(includes
squelch
adjust)
Provides monitor and carrier squelch adjust functions.
Position A: Squelch adjust mode (carrier squelch only)
Position B: Monitor on
Position C: Programmed squelch mode (monitor off)
Zone
Select
Selects Zone A, B or C.
Position A: First zone assigned in current bank
Position B: Second zone assigned in current bank
Position C: Third zone assigned in current bank
Talkaround Toggles channels between talkaround and repeater
modes.
Position A: Talkaround enabled
Position B: Talkaround disabled (repeater mode)
Position C: Talkaround disabled (repeater mode)
Hi/Lo
Power
Toggles the power setting from high to low. This
setting is programmed into each individual channel
and can be the same power level.
Position A: RF Power HI
Position B: RF Power LO
Position C: RF Power LO
The radio reads the toggle switch on power-up and
periodically. Setting is retained if battery is removed.
Encryption
Enables or disables encryption. The toggle positions:
Position A: TX encryption enabled
Position B: TX encryption disabled
Position C: TX encryption disabled
Disabled
Ignores any attempted use and provides an error tone.
Collar Switch
The 2-position (o, ΓΈ) collar switch located under the channel selector and is programmed using
the PC Programmer. The most useful function of this control is to enable/disable encryption of
the selected channel.