Technical data

22 Chapter 3 Hardware installation
NN40170-308
Use the following procedures to install a BCM50 unit in a rack:
To install the rack-mount shelf in an equipment rack on page 22
To install a BCM50 unit on the rack-mount shelf on page 22
To install the rack-mount shelf in an equipment rack
1 Determine the location in the rack where you want to install the BCM50 unit.
2 Position the rack-mount shelf in the rack.
3 Align the holes in the rack-mount shelf with the holes in the equipment rack rails.
4 Fasten the rack-mount shelf to the rack using the four rack screws (supplied with the
rack-mount kit).
To install a BCM50 unit on the rack-mount shelf
1 Place the BCM50 unit on the rack so that the feet of the unit fit in the depressions in the shelf.
2 Move the unit forward until the feet touch the front side of the depressions.
3 Slide the unit back until the feet click in place on the slots in the depressions. See the figure
Attach the units to the rack-mount shelf on page 22.
4 If you want to further secure the unit, use the four self-tapping screws (for plastic) supplied
with the rack-mount kit to attach the unit to the rack-mount shelf.
a Align the screw holes in the unit with the holes in the rack-mount shelf.
b Insert the four screws through the holes in the bottom of the shelf and into the screw holes
in the bottom of the unit.
Figure 3 Attach the units to the rack-mount shelf
Caution: Use only the screws supplied with the rack-mount kit (NT9T6325). Do not
replace the screws. Other screws can damage the unit.