Specifications
Strata CIX Programming 05/08 A-1
Applications Guide
Applications Guide A
This appendix contains guides to setup and program specific applications such as Voice Mail, IP
Telephony, StrataNet and others.
Voice Mail Set Up
The following steps/program sequences are provided as a guideline to programming System Voice Mail
settings.
Analog Ports
1. Program 100 Card Slot Assignment. Assign the PCB for Voice Mail ports (RSTU).
2. Program 200 Station Data. Verify FB1~FB4.
• FB03 Circuit Type – Assigns Voice Mail to be assigned to PDNs associated with Voice Mail RSTU
circuits.
• FB15 Display DN – DN to be displayed and assigned to Hunt Group. Manually assign DNs and
equipment.
3. Program 209 Station Hunting Group. Voice Mail Group is determined by the Hunt Group.
4. Program 218 Station Hunt Group Assignment.
5. Program 579 System Voice Mail Data. Complete FB01~FB17.
Notes
• FB10 Central Message Callback – Enter the node ID and hunt group for voice mail. Used for
centralized voice mail SMDI only.
• DTMF – Message Waiting Call Back DN across Strata Net TIE lines. DTMF integration uses the
number that displays in Program 200, field 15.
6. Program 580 Voice Mail Port Data. This is the collection of all ports.
7. Program 803 IO Logical Device Assignment. You can add members to the hunt group. Assign BSIS
RS-232 port for SMDI.
Note System only provides Code 300 for SMDI. Code 301 is not supported.
8. Program 804 BSIS RS-232 Serial Port setup.
9. Program 309 Direct Inward Dialing.
• FB11 DNIS VMID Code
• FB15 DID/DNIS Number DTMF VMID
10.Program 318 DID Intercept Assignment.
• FB11 VMID for DNIS Number
• FB15 DID/DNIS Number DTMF VMID