Specifications
Strata CIX Programming Guidelines
Use Default Auto-programming to Start Up
Strata CIX Programming Vol.1 05/08 1-9
Strata CIX
Programming
CIX Processor NIC Interface TCP/IP Auto-programming
The following are the initial values of the LAN data that is automatically created for the system.
• Network TCP/IP. See “916 IP Configuration” on page 10-16.
- IP address – 192.168.254.253
- Sub network master – 255.255.255.0
- Default gateway – 0.0.0.0
- IP routing table – Not used
• SNMP Agent settings
- Community name – communityName
- IP address – 0.0.0.0 (not restricted by the IP address of the access source)
- Privileges – WRITE
- community-id – 1
- User level – Super user
• Trap destination
- Community name – Nothing
- IP address – Nothing
• Modem PPP Server settings
- IP Address – 192.168.255.254 (Strata CIX modem fixed IP address for dial-up connections).
Table 1-14 Public Numbering Plan Analyzed Digit Numbers (Program 117
Public Numbering Plan Analyzed Number Public Numbering Plan Analyzed Digit Number
1NXX 11
N11 3
NXX 7
N = 2~9 and X = 0~9
Table 1-15 E911 Emergency Call to Outgoing Line Group (Program 550)
Emergency Call Group Number OLG1
11
Table 1-16 E911 Emergency Call Destination (Program 400)
System Mode Emergency Call Called Number Index Emergency Call Called Number
DAY1 1 200 or 2000 (the first PDN)
DAY2 1 200 or 2000 (the first PDN)
NIGHT 1 200 or 2000 (the first PDN)
The emergency call destination is set for the first PDN as 200 or 2000 in the all operation mode (DAY1, Day2,
NIGHT).