Specifications

IP Telephone Programming
IP Telephone Installation and Network Connection Setup
Strata CIX Programming 05/08 8-7
IP Telephone
Programming
05 TOS Precedence Type If TOS is selected in '04 TOS Field Type' select a packet priority level - where
Critical/ESP provides the highest and Routine provides the lowest priority.
If TOS is selected in '04 TOS Field Type' make selections in TOS Delay, TOS
Throughput Delay, and TOS Reliability Type.
Possible values:Routine, Priority, Immediate, Flash, Flash Override, or Critical/
ESP (Default)
TOS Delay Type If TOS is selected in '04 TOS Field Type' select 'Normal' for most cases
Possible values:Normal (Default) or Low
TOS Throughput Type If TOS is selected in '04 TOS Field Type' select 'Normal' for most cases
Possible values:Normal (Default) or High
TOS Reliability Type If TOS is selected in '04 TOS Field Type' select 'Normal' for most cases
Possible values:Normal (Default) or High
06 DSCP If DSCP is selected in '04 TOS Field Type' select a priority level from 0~63.
Possible values:0~63 (Default = 0)
07 IEEE802.1p Enable IEEE802.1p priority control if voice packets on an Ethernet LAN should be
prioritized with priority tagging. Higher priority, time-critical BIPU\IPT voice traffic
can have preferential treatment when other traffic is running at best effort. If you
enable IEEE802.1p, select which priority level to use (Voice or Best Effort) in '08
IEEE802.1p Configuration' on this screen. All Ethernet devices on the LAN
(routers, switches, etc., must support IEEE802.1p for this feature to work correctly.
Possible values:Enable or Disable (Default)
08 IEEE802.1p
Configuration
If 07 IEEE802.1p is enabled, select 'Voice' priority for BIUP\IPT voice packets to
be tagged with the highest priority level.
Possible values:Best Effort or Voice (Default)
09 IP-CTX Identifier Enter a CIX Node ID if more than one CIX Node is on the IP Network. This can be
the same as the Strata Net Node ID used for this system if it is in a Strata Net
Network - but the two IDs are not related in software logic. This ID must match the
Node 'number' programmed in the IP telephone.
Possible values:Up to 5 ASCII characters
10 Tail Length of Echo
Canceller
Enter 16ms if any IP telephone is set for a G729A codec (Prog 250-08) or if the
Strata Net IP Network is set for G729A codecs (Prg.672-06). If all codecs are
G711, then 16ms or 32ms can be used - 32ms may reduce echo on a network that
only utilizes G711 codecs. Never set this parameter to 64ms.
Note Setting G729A codec and 32 msec will reduce the number of channels
available from 16 to 12 or 32 to 24.
Possible values:16 (Default), 32 or 64MS
11 Gain Control of IPT
and BIPU
Set the Voice Quality Mode to control gain of IPTs and BIPUs.
Possible values:High (Default), Middle or Low
F
IELD DESCRIPTION