Specifications

Trunks
Service
Strata CIX Programming 05/08 6-23
Trunks
315 T1 Trunk Card
Prerequisite Program: 100 page 4-1
This command assigns T1 Trunk Card Data to the system.
1. Complete the Trunk Timer/DIT Record Sheet.
2. From the Program Menu, click Advanced Configuration > Trunk > T1. The T1 Trunk Card Data
Assignment screen displays.
3. Enter T1 card location in Shelf/Slot field (xxyy). The selected slot requires a DTU Card.
xx = Cabinet 01~07
yy = Slot 01~10
… or click the following buttons:
List choose from the list of programmed trunks on the right side of the screen.
Copy – to T1 trunk equipment.
Get Default - sets all data to factory defaults.
4. Enter values for Program 315.
5. Click Submit.
F
IELD DESCRIPTION
T1 Equipment Location Enter the RDTU PCB equipment location.
Enter data as XXYYZZ:
XX = cabinet 01~07; YY = slot 01~10; ZZ = analog trunk circuit 01~08 or
ZZ=T1channel 01~24.
Cabinet numbers:
CIX100: Select 01 for Base and Expansion cabinet.
CIX200: Select 01 for Base and 02 for Expansion cabinet.
CIX670: Select 01 for Base and 02~07 respectively for each Expansion cabinet.
Slot numbers:
CIX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CIX200: 01 ~ 04 for each cabinet.
CIX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
01 Coding Format Select the Coding Format.
Possible values:None, PZC, B8ZS (default), or ZCS
02 Frame Format Select the Frame Format.
Possible values:SF Mode or ESF Mode (default)
04 Receive PAD Select the Receive PAD values.
Possible values:None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB
05 Send PAD Select the Send PAD values.
Possible values:None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB