Specifications
Station
Assignment
5-20 Strata CIX Programming 05/08
36 Exclusive Hold Enable: If the user presses the Hold button twice in succession the
telephone places the current call on Exclusive Hold.
Disable: The telephone cannot place calls on Exclusive Hold.
Possible values:Enable or Disable (default = Enable)
37 Dial Directory -
Off Hook
Enable: Allows access to the telephone Dial Directory by going off-hook,
pressing the Spkr button or pressing the first softkey on the left side of the
LCD.
Disable: Denies access to the telephone Dial Directory by going off-hook or
pressing the Spkr button. User must press the first softkey on the left side
of the LCD to access the Directory Dial feature.
Note This option only applies to 7, 10, and 20 button telephones with
small LCDs.
Possible values:Enable or Disable (default = Disable)
38 Dial Directory -
Make Call
Enable: Allows user to originate a call by going off-hook, pressing the Spkr
button or pressing the CALL softkey after finding a name using the small
LCD telephone Dial Directory feature.
Disable: User must press the CALL softkey to originate a call using the
small LCD telephone Directory Dial feature. After finding a name, nothing
will happen when going off-hook or pressing the Spkr button.
Possible values:Enable or Disable (default = Disable)
39 LCD Keystrip
Type
Set this value to DP5130 for 9-line, large LCD telephones. For all other
telephones set this parameter to Not DP5130.
Note Parameter 03 of this command must also be set to 10 for a
DP5130.
Note To change this station from DP5130 to another type set this
parameter to Not DP5130, press Submit. Then change parameter
03 to a value other than 10.
Possible values:1: Not DP5130 (Default)
2: DP5130
40 ADM1 Keystrip
Type
Set this value to “LM5110” for a 10-line add-on module (LM5110). For all
others set to “Not LM5110”.
Possible values:1: Not LM5110 (Default)
2: LM5110
41 ADM2 Keystrip
Type
Set this value to “LM5110” for a 10-line add-on module (LM5110). For all
others set to “Not LM5110”.
Possible values:1: Not LM5110 (Default)
2: LM5110
To Remove an
LM5110 Add-on
Module
To remove an LM module (ADM 1 or ADM2)
1. Change FK 40 for ADM1, change FK 41 for ADM 2 to “Not LM5110” -
then click on Submit.
2. Change FK 4 to “One” or “None” as appropriate. - then click on Submit.
F