Specifications
Station
Assignment
Strata CIX Programming 05/08 5-7
Station
47 Personal Admin Password Enter the Personal Admin password for this station.
Possible values:0 ~ 16 characters (default = no data)
48 Personal Admin Level Enter the Personal Admin user privilege level for this station.
Possible values:Normal, Super1 or Super2 (default = Normal)
49 SLT MW/CLID Option Enter the Message Waiting control type and Caller ID (CLID) for this
standard telephone.
Two types of message waiting signaling are available on the BSTCIU: (1)
FSK Visual Message Waiting Indication (VMWI) for standard telephones
with CLID and Relay Control for a 90v message waiting lamp.
1. Relay control only - same as BSTU interface relay control of MW lamp
voltage with no CLID signaling. Some phones do not support message
waiting lamps. Refer the Prog. 208-08 (Station Timer assignments) to
disable or delay sending MW lamp signal.
2. Type 1 - No call waiting tone, with FSK VMWI.
3. Type 1 and Type 2 - with call waiting tone, with FSK VMWI
When using a BSTCIU to send CLID to a standard telephone option 2 or 3
must be selected to enable FSK signaling.
Possible values:1, 2, 3
Default: 1 - Relay control
50 Off-Hook Preference for SLT Enter Off-Hook Preference for this station.
Possible values:None (Internal Dial Tone) (default)
CO Line Access - Enter the line/trunk number
OLG - Enter the OLG number
LCR - Station will access LCR
For OLG or LCR - The station can dial the Override SLT CO Line
Preference code.
Table 5-1 Station Assignment Data for DKT, SLT and IPT1020SD Telephones (Continued)
F