Specifications

System
PAD Values
Strata CIX Programming 05/08 4-33
System
109 Music on Hold
Prerequisite Program: None
This command assigns external Music on Hold (MOH) and Background Music (BGM) sources.
1. From the Program Menu click Advanced Configuration > System > Music on Hold. The External Music
on Hold Source Assignment screen displays.
2. For fields 01~07, click in the adjacent radio button to activate MOH/BGM.
3. For fields 08~15, enter the equipment location identifier and check the Connected box to activate.
4. Click Submit.
F
IELD DESCRIPTION
MOH/BGM #1 (BECU) For MOH/BGM #2~#7, click in the radio button to enable MOH/BGM for
the specified BIOU (MOH/BGM #1 enabled by default).
Possible values:Enable (default) or Disable
MOH/BGM #2 (BIOU1-J1)
MOH/BGM #3 (BIOU1-J2)
MOH/BGM #4 (BIOU1-J3)
MOH/BGM #5 (BIOU2-J1)
MOH/BGM #6 (BIOU2-J2)
MOH/BGM #7 (BIOU2-J3)
MOH/BGM #8 (RSTU) Enter the RSTU equipment number to which MOH/BGM source #8 or
#9~#15 are connected. Enter data as xxyyzz:
Example: If the MOH/BGM source should be a assigned to an RSTU in
cabinet 5, slot 2, circuit 3, enter 050203.
A PDN can not be assigned to an RSTU equipment number if it is to be
a MOH circuit. If a PDN is assigned to the circuit that will connect to a
MOH/BGM source, you must first delete it using PRG201
Cabinet numbers:
CIX100: Select 01 for Base and Expansion cabinet.
CIX200: Select 01 or 02
CIX670: Select 01 for Base and 02~07 respectively for each Expansion
cabinet.
Slot numbers:
CIX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CIX200: Select 01 ~ 04 for either shelf.
CIX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
Notes
A PDN cannot be assigned to an RSTU equipment number if it is to be a
MOH circuit.
If a PDN is assigned to an MOH/BGM circuit, you must first delete the PDN
using PRG201
MOH/BGM #9 (RSTU)
MOH/BGM #10 (RSTU)
MOH/BGM #11 (RSTU)
MOH/BGM #12 (RSTU)
MOH/BGM #13 (RSTU)
MOH/BGM #14 (RSTU)
MOH/BGM #15 (RSTU)