Specifications
System
Dial Number Plan
4-18 Strata CIX Programming 05/08
26 Call Button Jumping Select whether to execute Jumping LED.
If enabled, line calls move from a telephone DN button to a line button after
they are answered. After the call is answered the DN button is cleared to
receive another call. With this operation the DN acts as an answer button
for the telephone. This operation only applies if the line that is answered
has a CO, GCO, or Pooled line button appearance on the telephone. If
disabled, line calls remain on the DN after they are answered.
Possible values:Enable (default) or Disable
27 Set Domestic Code Set to 0 (zero) to enable CIX to insert the leading zero when receiving a
National CLI.
29 CPN Numbering Plan Called Party Number numbering plan format.
Possible values: Unknown (default) or ISDN
30 SLT Recall Timer Hooking = 100ms, On-Off Hook = 500ms
31 Analog Trunk
Hunting
This parameter defines the order in which analog trunks are selected during
the outgoing call trunk selection process.
Possible values:Terminal (default) or Cyclical
32 Display Check Sum
Error
Enable a System Checksum error to be displayed and an error log to be
created.
Possible values:Enable or Disable (default)
33 Analog Tie Line
Disconnect Timer
Analog Tie Line Disconnect Timer enables tandem analog Tie Lines to
automatically disconnect if the timer expires.
Possible values:Enable or Disable (default)
34 Analog DID Method Analog DID method: Normal (DTMF)/MFC-R2 3 digits/MFC-R2 4 digits
Possible values:Normal (default), MFC-R2 3, MFC-R2 4
35 ALaw/MuLaw Choose the companding technique appropriate to the local PSTN. Mu Law
in North America.
Possible values:A Law or Mu Law (default)
39 Std. Tel. Ringing
Cadence
Select the Ringing Cadence for Standard Telephone circuits.
Note This does not apply to Digital or IP telephones.
Ringing Type 1
External Ring: 20Hz, 1sec. ON - 3sec. OFF
Internal Ring: 20Hz, 0.4sec.ON - 0.2sec. OFF 0.4sec. ON - 3sec. OFF
Recall:20Hz, 1sec. ON - 1sec. OFF
Ringing Type 2
Ringing Type2 is the same Ringing Cadence as DK.
External Ring:20Hz, 0.4sec. ON - 0.2sec. OFF 0.4sec. ON - 3sec. OFF
Internal Ring:20Hz, 1sec.ON - 3sec. OFF
Recall:20Hz, 1sec. ON - 3sec. OFF
F
IELD DESCRIPTION