User`s manual

1 DATECS EP-50
56 57
User’s Manual
[Caution] When the panel switch is disabled with this command, the LF switch
is disabled. Therefore, the paper cannot be fed by op erating the LF
switch.
[Default]
The initial value of n is “0”.
[Sample Program]
LPRINT CHR$ (&H1B) + “c5” + CHR$ (0); ¼¼
When enabling the LF switch
LPRINT CHR$ (&H1B) + “c5” + CHR$ (1); ¼¼
When disabling the LF switch
39. ESC d n
Printing and Feeding the paper by n lines
[Code] [1Bh] + [64h] + n
[Range] {0 <= n <= FFh}
[Outline] Prints data inside the buffer and feeds paper by n lines.
Specified line does not remain.
The beginning of the line is to be considered as the next printing
start position.
[Default]
The initial value is not defined.
[Sample Program]
LPRINT “AAAAA”
LPRINT CHR$ (&H1B) + “d” + CHR$ (2);
LPRINT “AAAAA” + CHR$ (&HA);
[Print Results]
2/6-inch line feed
Depending on n value, positional alignment is carried out as in the
table below:
0Left end alignment
1Centering
2Right end alignment
4Left end aligned vertical barcode
5Centered vertical barcode
6Right end aligned vertical barcode
[Default]
The initial value of n is “0”.
[Sample Program]
LPRINT CHR$ (&H1B) + “a” + CHR$ (0);
LPRINT “AAAAA” + CHR$ (&HA);
LPRINT CHR$ (&H1B) + “a” + CHR$ (1);
LPRINT “AAAAA” + CHR$ (&HA);
LPRINT CHR$ (&H1B) + “a” + CHR$ (2);
LPRINT “AAAAA” + CHR$ (&HA);
[Print Results]
Left-justified Centred Right-justified
Paper Feed Direction
38. ESC c5 n
Enabling/Disabling Panel Switches
[Code] [1Bh] + [63h] + [35h] + n
[Range] {0 <= n <= FFh}
[Outline] Selecting the LF switch valid/invalid.
“n” is valid only in the lowest bit (n0).
“n” bit means the followings.
0 LFSW valid.
1 LFSW invalid.