Schematic

RS-485 WIRELESS BRIDGE USER’S MANAUL REV. 02 13
Example:
Changing the baud rate from the default 9600 to 115200 bps.
Step 1: Using the X-CTU program, the XBee radio module is discovered on the data port – in this case
COM43. The baud rate is changed to 115200. The “Write” button is used to store the setting.
Fig. 10 X-CTU Baud Rate Setting
Step 2: On the Wireless Bridge information terminal (COM44 in this example) the set uart.rate 115200 is
issued followed by set store.