Datasheet

5
ACOu tlet110V /240V5A
2xACOutletatsame voltageasACInput(110~120/220~240V
accordingtomodel)
N.B.Socke tsareredun dan twhenPD1ispoweredfromDC
DCIn
ThePD1c anbepoweredfromasuitable12Vpowersource.When
workingfromDCthePD1willnotregulatethepoweroutlets.
Pleaseensurethatthe12Vpowersourc ethatyouuseisregulated.
IfyouintendtorunthePD1fromaca rorvanpoweroutletmake
surethatasuitableregulatorisusedon thepowerfeed.
Pin4shouldbewiredpositive andPin1shouldbeground.
N.B.TheACOutletsarenotactivewhenthePD1ispowered
viatheDCIn.
N.B.TheOn/Offswitchisredundan twhenthePD1ispowered
fromaDCsupply.
InputSelectAC/DC
TheInputselectswitchc anbesettoACorDCaccordingtothe
powerinputthatyouintendtouse.
N.B.Do notconnectACandDCpowerinlets atthe sametime.