Table of contents Warnings and Precautions -------------------------------------------------------------- 2 Radio and Television Interference ----------------------------------------------------- 3 Tech support--------------------------------------------------------------------------------- 4 The difference between model nos.
Warnings and Precautions 1. Read all of these warnings and save them for later reference. 2. Follow all warnings and instructions marked on this unit. 3. Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. 4. Do not use this unit in or near water. 5. Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious damage. 6.
Radio and Television Interference UNITED STATES: The equipment described in this manual generates and uses radio frequency energy. If it is not installed and used in accordance with the instructions in this manual, it may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Tech support It is our goal to make your products ownership a satisfying experience. Our supporting staff is available to assist you in setting up and operating your system. Please refer to our web site www.datavideo-tek.com for answers to common questions, support requests or contact your local office below. Datavideo Corporation (USA) 12300-U East Washington Blvd., Whittier, CA 90606 USA Tel: +1 562 696 2324 www.datavideo.
FEATURES 20 seconds of pre-event recording Stand alone NON-PC embedded system offering maximum stability Simple, easy to use control & user interface Near DVD quality MPEG2 recording and playback Video recording with Digital Watermark MP3-level high quality audio recording (32KHz sampling rate) Remote control panel Removable 2.
INSTALLATION Connect a RMC-110 10-Key Remote Control key pad for system configuration. N.B. Ensure that your camera connected and working, or you will get a “Video Loss” event.
INSTALLATION Connect a RMC-80 5-Key Remote Control key pad for the application in a vehicle. N.B. Ensure that your camera connected and working, or you will get a “Video Loss” event.
Introduction of RMC-110 10-Key Remote Control Key Pad 1. LCD: No Function 2. Turn ON / OFF Main Menu 3. Start / End Instant recording, Stop playback, Switch to Monitoring state 4. Turn ON / OFF Main Menu 5. Turn ON / OFF Event List Menu 6. Page down 10% of the entire list, instant Replay, instant Review 7. Select ZOOM in, GO back 8. Move the highlight up, Increase numbers, Switch characters upwards, Play / Pause ZOOM in 9.
Configure MP-4100 by RMC-110 Check Box serial number, firmware version and Box IP address Press on the “MENU” key on RMC-100 to Pop Up the “Main Menu”. Select “Information” and press on the Select “Box Information” and press on Press on key. You will enter the Information menu. key to find the Box serial number.
Check Hard Disk Info, Video System and Resolution Press on the key to pop up “Main Menu” Select “Information” and press on the Use the Press on the Press on the key, you will enter the Information menu. key to move the highlight and Select “Hard Disk Information”.
Check Log Information Press on the key to popup the “Main Menu”. Select “Information” and press on the Use the Press on the Press on the key to enter “Information menu”. key to move the highlight and select “Log Information”. key.
Video recording setting Press on the Use the Press on the key to pop up “Main Menu” key to move the highlight and select “Recording Settings” key to enter “Recording Settings” Menu Select “Recording Quality”, and then press Enter key Use the key to move around. Use the key to specify each item. Use the key to highlight the “Save” button and press on the save and pop up the System Settings menu.
Recording Video Quality There are 4 different bit-rates offered in MP-4100 (directly related to video quality) Recording Quality Bit-rate Quality Level High 3Mbps Near-DVD quality Fine 2Mbps Super VCD quality Normal 1.2Mbps VCD quality Low 800Kbps VCR-like quality Recording Frame Rate? There are 4 selectable frame rates in MP-4100 which are 30,10, 2 or1 fps for NTSC Video and 25,8.5,1.2,0.
Recording Time in a 60GB or 80GB HDD The estimated recording time on a 60GB HDD is about 46 hours with 30fps (NTSC video) and highest video recording quality (D1 resolution of 704 x 480) The estimated recording time on a 80GB HDD is about 61 hours with 30fps (NTSC video) and highest video recording quality (D1 resolution of 704 x 480) The estimated recording time on a 120GB HDD is about 92 hours with 30fps (NTSC video) and highest video recording quality (D1 resolution of 704 x 480) 14
Alarm Settings Press on the Use key to move the highlight and select “Recording Settings”. Press on the Use the Press on the Use the key on RMC-110 to pop up “Main Menu”. key to enter “Recording Settings” Menu key to move the highlight and select “Alarm Settings”. key to enter “Alarm Settings” Menu key to move around. Use the key to specify each item. Use the key to highlight the “Save” button and press the up the System Settings menu. Press on the “MENU” key to end the setup.
Change Network IP and MASK settings Press the Use the Press on the key on the RMC-110 Remote key to pop up the Main Menu. key to move the highlight and select “System Settings”. key to enter System Settings menu and select “Connection Settings”. Select “Ethernet Settings” and press on the key.
Use the key or key to enable or disable. Once DHCP is enabled, DVR can obtain the IP address automatically from your DHCP server. Otherwise, you need specify the following 3 items manually. Use the disabled. key or key to specify the 32-bit IP address manually, if DHCP is Use the disabled. key or key to specify the 32-bit subnet mask manually, if DHCP is Use the disabled. key or key to specify the 32-bit default gateway manually, if DHCP is Use the key or key to specify the 32-bit SAS IP address.
Format Hard Disk? Press on the “MENU” Use key to pop up “Main Menu”. key to move the highlight and select “System Settings”. Press on the key to enter “System Settings” menu and select “Format Hard Disk”. Select Format Hard Disk, then press Enter key Press on the “left” key to proceed Format HDD and press Enter key 18 to confirm.
Change DVR Serial Number Press on the key to pop up Main Menu and use the Select “System Settings” and press on the Select “Display Settings” and press on Use the right key Use the key to move the highlight. key to enter System Settings menu. key. to select DVR serial number key to move around and use the key to specify each item Use the key to highlight the “Save” button and press on the “System Settings” menu.
Set DVR Date and Time MP-4100 uses time and date as video index therefore it’s very important to make sure that your system time is set correctly when you first use it. Procedure to set the system clock: Press on the key to pop up “Main Menu” and use the key to move the highlight. key to enter System Settings menu. Select “System Settings” and press on the Select “Set Clock” from the System Settings menu and press on the Enter key Use the key to move around. Use the key to specify each item.
Set Date There are 3 fields for entering: Year Use the Month Use the Date Use the key to select a year between 2000-2016. key to select a month between 1-12. key to select a date between 1-31. Set Time There are 2 fields for entering: Hour Use the Minute key to select a minute between 0-59. Use the It is automatically changed when the hour passes11. am/pm key to select an hour between 0-12.
Basic Operation with RMC-80 PLAY RECORD UP DOWN STOP Recording MP-4100 supports Instant Recording, Alarm/Event Recording and Video Loss Recording. You may always use the key on RMC-80 to start or end an instant recording. Whenever an event is detected, system will start the event recording. Following status icons and message bars will be displayed on the top of screen, when a recording starts.
Remote Monitoring MP-4100 supports remote live monitoring, recording, playback, automatic email alert and software upgrade. To use these features, you need to connect your DVR to Internet or local network, and setup the Ethernet Settings. Remote Monitoring After setting up networking for MP-4100, You may remote monitor your DVR from any PC. Note: Please make sure your DVR is connected to Internet or local network. Simply open an Internet Explorer, enter your DVR’s IP address.
Network setting for MP-4100 and the PC Connect the MP-4100 to Internet Network *. Note: To install MP-4100 in the Internet xDSL network, it requires at least two fixed IP from ISP, one for the Router of xDSL modem (Usually the xDSL Modem will build-in Router function) the other one for MP-4100.
1. Setup MP-4100 IP and MASK Press the Use the Press on the key on the RMC-110 Remote key to pop up the Main Menu. key to move the highlight and select “System Settings”. key to enter System Settings menu and select “Connection Settings”. Select “Ethernet Settings” and press on the key.
2.
27
Launch IE with the DVR IP address to connect PC with MP-4100 thru Ethernet.
Event downloaded and view on PC thru Ethernet Operation Procedure Step1: Connect MP-4100 Ethernet port to Intranet/Internet Step 2: Launch IE with the DVR IP address from MP-4100 Step 3: Key in the User Name: supervisor and Password: three Step 4: on the Main Page, select “Remote Backup” 29
Step 5: click on the Event list. Step 6: click on the mouse Right button and select Save Target AS.
Step 7: Click on the “Save” Step 8: Please wait to download complete mpeg file.
Step 9: Click on the “Close” Step 10: Click on the “Back” to last page 32
Step 11: Click on the “Back” again to last page.
Step13: Key in User Name: supervisor and Password: three Step14: Click on the mouse right button and select “Open” 34
Step 15: Open an event file.
How to update firmware 1. Connect MP-4100 to Intranet and power on MP-4100 2.
3. On main menu select "System Administration", in "System Administration" page, 4. Press the button “Browser…" to find the update software of “Flashimg.
5. Click on the button 6. Select path to file Flashimg.
7. Open the flashimg.eap 8.
9.
10. “ Found a new code, upgrade?” should appear on the TV Monitor; if it does not, type the following address in IE's address input MP-4100: http://192.168.1.175/cgi-bin/command.cgi?device=flash&command=upgrade¶m1=a:\flashimg.eap Note: You need to change 192.168.1.175 to your MP-4100's IP address 11.On TV Monitor, dialogs will popup as below “ Found a new code, upgrade?” Please use the RMC-80 down or up key to select " RMC-80 to proceed firmware update. " and press on the “Play” key on 12.
Accessories GPS Text Overlay Box (VP-364) Specification: *. Supports two RS-232 serial interface for GPS Navigator communication and Remote control *. GPS communication Spec: Proprietary protocol at 19200 bps, 8 Data bit, 1 Stop bit, No Parity *. OSD Spec: 12 Text line (Row) 24 characters per line (Column) *. Text overlay display Longitude and Latitude Speed by MPH or KPH Time and Date *. Video spec Composite Video Input and Output (BNC, 75 ohm, 1.0Vp-p) *. Additional two channels Trigger input terminal.
Connecting a GPS Text Overlay box in the system LCD Monitor MP-4100 Rear Panel GPS Navigator GPS TEXT OVERLAY BOX 43
F.A.Q. 1. Why does it take a long time to reboot my DVR? The normal reboot time should be less than 5 seconds. If you experienced a longer time on reboot, it might be because your DHCP server couldn’t be found. You should disable DHCP in MP-4100 unless you are certain the DVR is connected to a DHCP server. 2. When I remote monitor my DVR, the video I get looks jerky even though I set the frame rate as 30fps. Your network bandwidth also affects the smoothness of the video you receive.
All the trademarks are the properties of their respective owners. Datavideo Technologies Co., Ltd.