User`s manual
DT-6X60 User's Manual - Platform (Build 2.0)
12 APPENDIX F: DT-6X60 S
PECIFICATIONS
To maintain compliance with the above-mentioned EMC standards, shielded cables must be
used on all
DT-6X60
interface connections, and the shields must make an electrical
connection to the
DT-6X60
's grounding system.
12.1 C
ONSOLE
P
ORT
A standard RS-232C interface that uses binary data interchange between DTE and DCE. This
interface uses an RJ45 connector and operates at 9600 bits per second (bps), 8 bits per character,
no parity, and one stop bit.
12.2 10/100 LAN P
ORT
The 8-pin LAN modular connector is used to interface to a 10/100 Mbps baseband CSMA/CD local
area network.
12.3 P
HYSICAL
D
IMENSIONS
L= 16.9 x W=8.77 x D=1.72
12.4 E
NVIRONMENTAL
O
PERATING
R
ANGE
Operating Temperature: 5° to 40°C (41°F to 104°F) per GR-63-CORE.
Operating Humidity: 5% to 85%
Altitude: From 60 m (197 ft.) below sea level to 4000 m (13122 ft)
Table 10: Environmental Operating Ranges
12.5 R
EGULATORY
I
NFORMATION
Safety: UL listed U.S. and Canada
EMC: FCC Part 15B Class A, ICES-003 Class A
NEBS:
Level 3 Compliant – designed and built to applicable GR-1089-CORE
and GR-63-CORE requirements
06/07/07
Datatek Applications Inc. 64
Table 11: Regulatory Information