User`s manual

DT-6X60 User's Manual - Platform (Build 2.0)
To delete all values for a keyword, type the word “none” as the value. Special characters and
escape sequences are accepted for community strings, sysName, sysLoc, and sysContact
parameters, but must be entered at the prompt for that parameter, not on the command line.
When the SNMP configuration is changed, the agent is restarted. Whenever the DT-6X60 reboots
or the agent is restarted, a warm-start trap is sent to the configured trap manager. The only other
trap sent by the DT-6X60 platform agent is "authentication fail" when a manager attempts to use a
community name not on the list. This trap is only sent if a manager has enabled it to be sent.
The snmp sysName, sysLoc, and sysContact are changeable via an SNMP manager as well as
via the console.
The enterprise object ID of the DT-6160 platform is 1.3.6.1.4.1.3791.3.
13,
for the DT-6260 it is 1.3.6.1.4.1.3791.3.
14,
and for the DT-6061 it is 1.3.6.1.4.1.3791.3.
7