If parameters are omitted from the command line, install will prompt for them. When prompted for
the password, input is not echoed. Note that it is necessary to specify ID and PASS only if the FTP
server is not a standard anonymous FTP.
The install command remembers the last SRV and LOC and provides them as defaults for the SRV
and LOC prompts.
Multiple applications may be downloaded from the same SRV and LOC in a single invocation of
install. This is accomplished by listing all the application names separated by commas with NO
spaces as the value of NAME: e.g. install NAME=tn3270,x25pad etc.
Only applications that have been built to be compatible with the platform software in a DT-6X60
can be used in a DT-6X60. Consult the latest release notes for DT-6X60 platform software to see
the current list or the release notes for the particular application.
6.5.4 APPLICATION SOFTWARE REGISTRATION - REGAPP
Syntax: regapp [ <key> ]
Each application that is installed or upgraded on a DT-6X60 must be registered in order for it to
run. Please contact Datatek for a registration key. The key is based on the application name, the
software version (the two-part build number, e.g. 9.1) of the application software, and the
hardware serial number and MAC address of the DT-6X60. An unregistered application may be
assigned to instances, but they will not start until the application is registered.
The regapp command accepts a key on the command line. If the key matches an installed
application, that application becomes registered. If a key is not given on the command line, a list of
unregistered applications is displayed followed by the module hardware information. Then the user
is prompted for a key.
6.5.5 APPLICATION ASSIGNMENT TO INSTANCE(S) - APP
Syntax: app <instance> [cnt=<number>] [type=<type>|none]
As noted earlier, the DT-6X60 simultaneously supports many instances of different applications.
The number and type of application must be configured as a system parameter. This is done with
the app command. The app command will allow the installation of any supported and properly
installed application into an instance. There are N such instance slots available (30 for a DT-6160
and 48 for a DT-6260). Any combination of applications is supported with two exceptions. For
either the IP-LTCN or IP-VCON applications, the application is installed in instance 1 only, and
must be the only application assigned to an instance in the processor.
The <instance> is the location where the selected application is to be installed. There exist N such
instances on the DT-6X60. If there was a prior application in the location specified, it is replaced by
the new application.
The cnt=<number> is an optional parameter that allows multiple consecutive instance locations to
be configured identically. When this parameter is not used, the number of instances affected by the
command is one. (Previous versions of the DT-6X60 used num= for this purpose. The older syntax
is still supported.)
The type=<type> is a required parameter that defines the application to be installed in the
instance specified. If the value is NONE, then any application in the instance specified is deleted
(including its configuration). The type must be the name of an application previously installed on
the DT-6X60 by the install command.
6.5.6 RESET AN APPLICATION PASSWORD - RSTAPP
06/07/07 Datatek Applications Inc. 30
Syntax: rstapp <instance>