User`s manual
DT-6X60 User's Manual - Platform (Build 2.0)
5 QUICK-START C ONFIGURATION G UIDE
There are two levels of configuring a DT-6X60: platform and application. This user manual covers
only the platform configuration and registration, and the installation and registration of the
application software. The commands and IP addressing associated with configuring an application
in an instance are described in the corresponding User Manual for that application. Those manuals
are available on the Datatek web site.
Below is a sample configuration sequence for a DT-6X60 platform. The initial Platform
Configuration sequence must be entered via the hard-wired serial console connected to the CON
port of the DT-6XXX. After the Platform Configuration sequence has been performed, platform
console operations may be conducted either via the hard-wired serial console or by connecting
from a third party host through telnet to port 1023 of the platform’s configured IP address.
5.1 P
LATFORM
C
ONFIGURATION
The following is the command sequence for the initial configuration of the DT-6X60.
<DT-6X60> login passwd=initial ↵ enter "logged: in mode
User is logged in
<DT-6X60> date 11:05:00 04/22/2004 ↵enter date & time (optional)
Thu Apr 22 11:05:00 EDT 2004
<DT-6X60> ipaddr 135.17.59.240 ↵ enter IP address of DT-6X60
You must reboot for this change to take effect
<DT-6X60> submask 255.255.255.0 ↵ enter Subnet Mask of DT-6X60
You must reboot for this change to take effect
<DT-6X60> gateway 135.17.59.1 ↵ enter Gateway Address of DT-6X60 if necessary
You must reboot for this change to take effect
<DT-6X60> reboot ↵
5.2 P
LATFORM
S
OFTWARE
R
EGISTRATION
The software for this product must be registered in order to run applications. Please call Datatek
for a registration key. The key is based on the product code (DT-6X60), the two-part software
release number (release.version)
1
of the platform software, and the hardware serial number and
MAC address of the DT-6X60.
<DT-6X60> register ↵
Product_Code=DT-6X60
MAC=0.96.29.99.99.99
HW_SERNUM=99.99.99.99.99.99
Build_Number=16.0
Build_Date="Mon Feb 2 14:21:02 EST 2004"
Enter key: rxyuvw8s
Registration successful
5.3 A
PPLICATION
I
NSTALLATION
This action requires that a host, acting as an ftp server, is present on a network that is accessible
by the DT-6X60 install command.
06/07/07 Datatek Applications Inc. 17
1
Also called the Build Number.