3) Attach the LAN data transport cable
4) Attach console cable by plugging one end of an RJ45-terminated twisted-pair data cable into the DT-
6X60 console interface and the other into the port of the asynchronous device that will be used to
configure or manage the DT-6X60.
5) Plug the power supply into a standard 115V AC outlet and the barrel connector on the power
supply cable into the circular connector on the faceplate labeled 24V DC.
3.3 I
NSTALLATION FOR
DC O
PERATION
1. Stand-Alone: Attach the provided feet to the bottom of the unit
Rack-Mount: Attach the mounting brackets to each side of the DT-6X60.
2. Stand-Alone: Fasten the strain relief to the side of the DT-6X60.
Rack-Mount: Fasten the strain relief to the DT-6X60 rack-mount bracket.
3. Stand-Alone: Place the DT-6X60 in the desired location, such as a shelf in a data equipment
rack.
Rack-Mount: Fasten the DT-6X60 to a 19-inch equipment rack (using appropriate rack screws)
or use extension ears for a 23-inch rack.
4. Attach the LAN transport cable.
5. Attach console cable by plugging one end of an RJ45-terminated twisted-pair data cable into
the DT-6X60 console interface and the other into the port of the asynchronous device that will
be used to configure or manage the DT-6X60.
6. Run 48V DC (return, -48, and ground) wires from a central source through the strain relief
clamp for DC wire stabilization. On the DT-6X60 faceplate, attach the return, -48, and ground
wires to the return, -48, and ground connections, respectively, on the terminal block labeled
48V DC.
7. Rack-Mount: The Environmental Operating Range of 5 to 40 degrees C (41 to 104 degrees F)
is necessary to maintain compliance with UL.
3.4 I
NSTALLATION FOR
P
OWER
O
VER
E
THERNET
(POE) O
PERATION
1. Stand-Alone: Attach the provided feet to the bottom of the unit.
Rack-Mount: Attach the mounting brackets to each side of the DT-6X60.
2.
Stand-Alone: Place the DT-6X60 in the desired location, such as a shelf in a data equipment
rack.
Rack-Mount: Fasten the DT-6X60 to a 19-inch equipment rack (using appropriate rack screws)
or use extension ears for a 23-inch rack.
3. Attach console cable by plugging one end of an RJ45-terminated twisted-pair data cable into
the DT-6X60 console interface and the other into the port of the asynchronous device that will
be used to configure or manage the DT-6X60.
4. Connect an ethernet cable to the 10-100 Base-T port and the other end to a POE Injector. The
POE Injector is connected by a second ethernet cable to the local hub or router.
06/07/07 Datatek Applications Inc. 13
5. Connect the POE Injector to the output of a power supply that provides at least 200 mA at –
48V DC. (This capability was tested with a HyperLink Technologies Model BT-CAT5-P1
ethernet injector using a HyperLink Technologies Model PSU15B-8 Power Supply. That supply
has an input of .5 A at 100 –240 V AC and output of .31 A, 15 watt maximum at –48 V DC.)