3 INSTALLATION
This chapter contains the steps needed to install and cable the DT-6X60. A #2 Phillips and
medium-sized flathead screwdrivers are required.
Figure 3: DT-6X60 Front View
3.1 R
EQUIRED
E
QUIPMENT
3.1.1 FOR BOTH RACK-MOUNT AND STAND-ALONE INSTALLATIONS
To install either a rack-mounted or stand-alone DT-6X60, the following items are needed:
One DT-6X60 unit
For AC operation, AC power supply
For DC operation, a strain-relief clamp for wire stabilization
A standard RJ45 terminated Category 5 twisted-pair data cable for the LAN port
connection.
A console cable that may require special wiring depending on the type of console used.
(Console Cables – refer to CABLING section 4.1 below to determine specific requirements
for this installation.)
Note: Shielded cables must be used in order to maintain compliance with EMC
requirements.
3.1.2 FOR RACK-MOUNT INSTALLATIONS ONLY:
An EIA standard 19-inch or 23-inch equipment rack with internal, vertical mounting rails.
Hole spacing on the vertical-mounting rail must be 1.25 inches. Use the dimension
specifications to calculate how high the rack needs to be to support the required number of
DT-6X60 units.
A pair of mounting brackets for each DT-6X60.
The Environmental Operating Range of 5 to 40 degrees C (41 to 124 degrees F) is
necessary to maintain compliance with UL.
3.2 I
NSTALLATION FOR
AC O
PERATION
1) Stand-Alone: Attach the provided feet to the bottom of the unit
Rack-Mount: Attach the mounting brackets to each side of the DT-6X60.
06/07/07 Datatek Applications Inc. 12
2)
Stand-Alone: Place the DT-6X60 in the desired location, such as a shelf in a data equipment
rack.
Rack-Mount: Fasten the DT-6X60 to a 19-inch equipment rack (using appropriate rack screws)
or use extension ears for a 23-inch rack.