User`s manual
DT-6061 User's Manual - Platform (Build 17.1)
12/14/09
Datatek Applications Inc. 30
If a DT-4XXX or UMI at address 'C' has been permanently removed from the network or no
longer has connections configured with this DT-6XXX, it is beneficial to delete 'C' from the
dtproduct configuration of this DT-6XXX.
The absence of one or more DT-4XXX's from the network when they occur in the dtproduct
list on a DT-6XXX can cause up to a 10-second (total) delay when rebooting that DT-6XXX.
There is very little overhead in adding 'D' to a dtproduct configuration of a DT-6XXX, as long
as the DT-4XXX associated with 'D' is usually up and running when this DT-6XXX is
rebooted; otherwise the 10 second boot delay described above may apply. However, a list
larger than 40 or 50 should be carefully managed.