5 QUICK S TART C ONFIGURATION G UIDE
There are two levels of configuring a DT-6061: platform and application. This user manual covers
only the platform configuration and registration, and the installation and registration of the
application software. The commands and IP addressing associated with configuring an
application in an instance are described in the corresponding User Manual for that application.
Those manuals are available on the Datatek web site.
Below is a sample configuration sequence for a DT-6061 platform. The initial Platform
Configuration sequence must be entered via the hard-wired serial console connected to the CON
port of the DT-6061. After the Platform Configuration sequence has been performed, the unit may
be connected to a network and platform console operations may be conducted either via the
serial console or by connecting from a third party host through telnet to port 1023 of the platform’s
configured IP address.
5.1 P
LATFORM
C
ONFIGURATION
The following is the command sequence for the initial configuration of the DT-6061.
<DT-6061> login passwd=initial enter "logged: in mode
User is logged in
<DT-6061> date 11:05:00 09/22/2003 enter date & time (optional)
Fri Sep 22 11:05:00 EDT 2003
<DT-6061> local prepare to enter IP parameters
IP address ? (192.168.15.21) ipaddr=135.17.59.240 enter IP address
local subnet mask ? (255.255.255.0) submask=255.255.255.0 Subnet Mask
IP address of gateway ? (192.168.15.1) gateway=135.17.59.1 Gateway IP
You must reboot for this change to take effect
<DT-6061> reboot
5.2 P
LATFORM
S
OFTWARE
R
EGISTRATION
The software for this product must be registered in order to run applications. Please call Datatek
for a registration key. The key is based on the product code (DT-6061), the two-part software
release number (release.version)
1
of the platform software, and the hardware serial number
and MAC address of the DT-6061.
<DT-6061> register
Product_Code=DT-6061
MAC=0.96.29.99.99.99
HW_SERNUM=99.99.99.99.99.99
Build_Number=17.1
Build_Date="Tue Nov 25 10:45:25 EST 2008"
Enter key: rxyuvw8s
Registration successful
1
Also called the Build Number.