DT-6061 Embedded Network Processor Platform User's Manual RELEASE.VERSION 17.1 379 Campus Drive, Suite 100 Somerset, NJ 08873 fax: 732 667-1091 phone: 732 667-1080 email: sales@datatekcorp.com http://www.datatekcorp.
DT-6061 User's Manual - Platform (Build 17.1) TABLE OF CONTENTS TABLE OF CONTENTS .......................................................................................2 TABLE OF FIGURES AND TABLES ...................................................................5 Important Safety Instructions ............................................................................7 1 Introduction....................................................................................................8 1.1 1.
DT-6061 User's Manual - Platform (Build 17.1) 6.3.4 6.3.5 6.3.6 6.3.7 6.3.8 6.3.9 6.4 System Label Configuration - label ....................................................................... 23 Configure the Banner - banner .............................................................................. 23 Date and Timezone.................................................................................................. 24 Change Password - chgpass ........................................................
DT-6061 User's Manual - Platform (Build 17.1) 6.9.3 6.9.4 6.9.5 6.9.6 Automatic Standby Configuration Update – stby cfg.......................................... 45 Standby Logs – stby dlog, stby reset ................................................................... 46 Switchover ............................................................................................................... 46 Commands Not Available in Standby Mode.........................................................
DT-6061 User's Manual - Platform (Build 17.1) 14 End-User License Agreement for Software...............................................70 14.1 14.2 14.3 14.4 14.5 14.6 14.7 Software License ........................................................................................... 70 Intellectual Property Rights .......................................................................... 70 Software Support ...........................................................................................
DT-6061 User's Manual - Platform (Build 17.1) Table 9: TCP/UDP Port Numbers Used ........................................................... 53 Table 10: Environmental Operating Ranges................................................... 66 Table 11: Regulatory Information .................................................................... 67 Table 12: Power Requirements........................................................................ 69 12/14/09 Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) Important Safety Instructions ! The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
DT-6061 User's Manual - Platform (Build 17.1) 1 INTRODUCTION The DT-6061 (Embedded Network Processor) is a network applications computer that applies customer specific protocol operations (protocol translation and termination) of network connections that require such a function in a distributed network. This product has many similarities with DT-6160 and DT-6260, but has different power options and capabilities.
DT-6061 User's Manual - Platform (Build 17.1) 1.1 MULTIPLE APPLICATION SUPPORT The DT-6061 can support one or more different types of applications and up to 30 instances of each application with a few exceptions. An application instance can be described as a unit of configuration parameters as a specific DT-6061 application defines them.
DT-6061 User's Manual - Platform (Build 17.1) Application Name Description Eliminates the need, complexity, and expense of specialized X.25 equipment in an IP network by allowing an X.25/BX.25 device, such as a network element's OS port, to be connected to a synchronous port anywhere in the IP network and communicate with a host via IP. X25PAD Additional description for each application is provided in section 0, Appendix E.
DT-6061 User's Manual - Platform (Build 17.1) 2 PHYSICAL DESCRIPTION Figure 2: DT-6061 Front View 2.1 2.1.1 POWER INTERFACES DC POWER The DT-6061 rack-mount or stand-alone accepts DC power input directly from a 48V DC power source and connects into the three position (accepting return, minus and ground, power wires) terminal block labeled 48V DC on the DT-6061 faceplate. The terminal block connectors accommodate 10 awg to 14 awg (American Wire Gauge) wire.
DT-6061 User's Manual - Platform (Build 17.1) 2.4 10BASE-T LAN These two interfaces require a standard RJ45 terminated Category 5, twisted pair, data cable. They connect to a 10BaseT hub or Router on the local LAN segment. The left connector is labeled LAN2 and the right one LAN1. The LAN2 connector is not currently used. 2.5 LEDS The DT-6061 faceplate contains light emitting diodes (LEDs) used to report DT-6061 activity and behavior.
DT-6061 User's Manual - Platform (Build 17.1) 3 I N S TA L L AT I O N This chapter contains the steps required to install and configure the DT-6061. Figure 3: DT-6061 Front View 3.1 EQUIPMENT Unpack and inspect the DT-6061 unit and other components and have on hand a #2 Phillips and medium-sized Flathead screwdriver. 3.1.1 POWER RECONFIGURATION STEPS FOR 115V AC (-5V DC) OR –48V DC OPERATION The DT-6061 is powered through either of two interfaces: –48V DC or –5V DC input.
DT-6061 User's Manual - Platform (Build 17.1) DT-6061 unit(s) AC to DC power supply(s). –48 VDC is directly wired into the unit. Cables (see Cabling section for required Data and Console cable types and their configuration). A strain relief clamp for wire stabilization (-48V DC operation ONLY). An EIA standard 19-inch or 23-inch equipment rack with internal, vertical mounting rails. Hole spacing on the vertical, mounting rail must be 1.25 inches.
DT-6061 User's Manual - Platform (Build 17.1) 5) Attach console cable by plugging 1 end of the RJ45 terminated, twisted pair, data cable into the DT-6061 console interface and the other into the port of the asynchronous device that will be used to configure or manage the DT-6061 (see Cabling section). 6) Run your 48V DC (return, minus and ground) wires from a central source through the strain relief clamp (for DC wire stabilization).
DT-6061 User's Manual - Platform (Build 17.1) 4 CABLING 4.1 4.1.1 SERIAL CONSOLE CONNECTION AND CONFIGURATION CABLING THE DT-6061 SERIAL CONSOLE This section describes the options for cabling a DT-6XXX serial console port, to allow the DT6XXX platform to be managed by a terminal, PC, dial-up modem, or asynchronous network connection.
DT-6061 User's Manual - Platform (Build 17.1) Important! A modular cable with “SPECIAL WIRING” can be ordered using the table above or built using the wiring diagrams provided in this manual in section 7. The pin-outs for the 9-pin connector is shown in section 0. 4.1.2 4.2 CONSOLE CONFIGURATION NOTES FOR BNS-2000/BNS-2000 VCS NETWORKS Configure SAM, TY12 and MSM console connections as 9600 bps with 8 bits and no parity, and use a DCE type cable.
DT-6061 User's Manual - Platform (Build 17.1) 5 Q U I C K S TA R T C O N F I G U R AT I O N G U I D E There are two levels of configuring a DT-6061: platform and application. This user manual covers only the platform configuration and registration, and the installation and registration of the application software. The commands and IP addressing associated with configuring an application in an instance are described in the corresponding User Manual for that application.
DT-6061 User's Manual - Platform (Build 17.1) 5.3 APPLICATION INSTALLATION This action requires that a host, acting as an ftp server, is present on a network that is accessible by the DT-6061 install command. install ↵ application or package name ? NAME=tn3270 ↵ name of ftp download server ? SRV= ↵ login on download server ? ID= ↵ password ? PASS= ↵ name of directory on server ? LOC=(/dt6061/apps) application> ↵ Downloading "tn3270" ...
DT-6061 User's Manual - Platform (Build 17.1) 6 D T- 6 0 6 1 C O M M A N D R E F E R E N C E All DT-6XXX software is composed of two components. One component, called the Platform, exists to support all applications. The second component is comprised of the individual application(s). The Platform provides Operating System functions, selected interfaces, protocol stacks, SNMP functions, and system OA&M while each application uses the services of the resident Platform.
DT-6061 User's Manual - Platform (Build 17.1) The banner and some of the parameters of the snmp command entered in response to prompts can use any special characters. Backspace erases one character and @ deletes the current line of input. The del key kills most commands. An optional timeout can be configured for the console; if a command is not completely entered within the configured timeout period (in the range of 30 to 1000 seconds), the console is automatically logged off.
DT-6061 User's Manual - Platform (Build 17.1) Table 5: Command Reference table Section Number Category 6.3 System Platform Configuration - Non IP Network Commands 6.4 12/14/09 System Platform Configuration - IP Network Commands 6.5 Software Administration Commands 6.6 6.7 System Reset Command SNMP 6.8 Run-Time Commands 6.9 Duplex Operation Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) 6.3 6.3.1 SYSTEM PLATFORM CONFIGURATION – NON IP NETWORK COMMANDS SYSTEM CONSOLE USER HELP - HELP Syntax: help | ? [command] The available commands on the DT-6XXX system console, along with a short narrative, is available via the help or “?” command. Command-specific help is available as well. For example, help "L" shows help for all commands that begin with "L" or help "login" shows help for this specific command. 6.3.
DT-6061 User's Manual - Platform (Build 17.1) a newline (enter). The user is again prompted for a line number. When finished, the user types a newline in response to the line number prompt. The character set allowed for the banner is not restricted by the input rules of section 6.1. Any characters may be entered for the banner. The @, \, and backspace characters may be entered only by preceding them with \. 6.3.
DT-6061 User's Manual - Platform (Build 17.1) 6.3.7 CHANGE PASSWORD - CHGPASS Syntax: chgpass OLD= NEW= CONFIRM= The chgpass command is used to change a user password on the system console. The command is only allowed if the user is logged in. All three parameters can be given on the same line as the command. None of those entries are echo-suppressed. However, if parameters are omitted from the command line, the console will prompt for them, and the responses will be echo-suppressed.
DT-6061 User's Manual - Platform (Build 17.1) 6.4 6.4.1 SYSTEM PLATFORM CONFIGURATION – IP NETWORK RELATED COMMANDS CLOSED USER GROUPS - CUG Syntax: cug [ipaddr=][submask=] The cug command is only allowed when the unit is logged in. The parameter is the closed user group identifier used to assign the CUG to the telnet platform console (with the console command) or to the SNMP interface (with the SNMP command).
DT-6061 User's Manual - Platform (Build 17.1) The IP address and subnet mask are used to determine whether a destination IP address is on the same LAN segment, or if a gateway hop is required. If it is necessary to reconfigure a DT6XXX to a new subnetwork, first set the gateway to none, then change the ipaddr, then set the new gateway. When one of these commands is invoked without its argument, it will display the current configuration of the unit.
DT-6061 User's Manual - Platform (Build 17.1) The optional simplex parameter can be used to switch the unit from redundant to simplex, while the duplex parameter can be used to switch the unit from simplex to redundant. Please refer to sections 6.4.3 and 6.4.4 for the significance of the parameters. Changes to these system parameters do not become effective until after the next reboot. 6.4.6 HOSTNAME Syntax: hostname [
DT-6061 User's Manual - Platform (Build 17.1) Each ipaddr field is the IP address of a Domain Name Server to be used to resolve domainstyle addresses not defined in the hosts table. The DNS IP addresses are used in the order specified. If only one address is to be defined, it should be ipaddr1. Each time the dns command is run, the user is prompted for all values except for those specified on the command line. The user is prompted in the following order: name1, name2, name3, ipaddr1, ipaddr2, ipaddr3.
DT-6061 User's Manual - Platform (Build 17.1) If a DT-4XXX or UMI at address 'C' has been permanently removed from the network or no longer has connections configured with this DT-6XXX, it is beneficial to delete 'C' from the dtproduct configuration of this DT-6XXX. The absence of one or more DT-4XXX's from the network when they occur in the dtproduct list on a DT-6XXX can cause up to a 10-second (total) delay when rebooting that DT-6XXX.
DT-6061 User's Manual - Platform (Build 17.1) 6.5 SOFTWARE ADMINISTRATION COMMANDS 6.5.1 INSTALLING A PLATFORM UPGRADE - INSTALL Syntax: See section 6.5.3 below. Platform upgrades use the install command using the same approach as application installation, with platform upgrades distinguished from application installation in the naming of the upgrade files. Platform upgrades are always named basexupd.
DT-6061 User's Manual - Platform (Build 17.1) If parameters are omitted from the command line, install will prompt for them. When prompted for the password, input is not echoed. Note that it is necessary to specify ID and PASS only if the FTP server is not a standard anonymous FTP. The install command remembers the last SRV and LOC and provides them as defaults for the SRV and LOC prompts. Multiple applications may be downloaded from the same SRV and LOC in a single invocation of install.
DT-6061 User's Manual - Platform (Build 17.1) (including its configuration). The type must be the name of an application previously installed on the DT-6XXX by the install command. 6.5.6 RESET AN APPLICATION PASSWORD - RSTAPP Syntax: rstapp Each application instance is allowed to have its own user changeable password for configuration purposes. In the event that the password is lost, it may be necessary to reset this password back to the initial value.
DT-6061 User's Manual - Platform (Build 17.1) IP address of the DT-6061 or the configured label. The user may choose a unique name for FILE (the default name is bkup). The back and retr commands remember the previous SRV, LOC, and FILE values and provide them next time as defaults for the SRV, LOC, and FILE prompts. 6.5.8.1 DT6BACKUP AND DT6RELOAD UTILITIES A new set of utilities is available which allows the mechanization of the backup and retrieve/reload processes.
DT-6061 User's Manual - Platform (Build 17.1) non-volatile memory. There is only one trap=. The dest= parameter configures the IP address of the target trap manager. The snmp vfy command (same as vfy snmp) displays the current settings of SNMP configuration. The snmp command prompts for all parameters not specified on the command line. Simply type snmp in order to add or change any parameters.
DT-6061 User's Manual - Platform (Build 17.1) 6.8 6.8.1 RUN-TIME COMMANDS DISPLAY CONNECTIONS – DC OR DCONN Syntax: dc | dconn [app [app#]][ -f ] [ -a ] The DT-6XXX may have thousands of TCP connections to other elements. A complete list of these connections is reported by the dc (or dconn) command. The optional -a causes the report to include the listening ports awaiting connection requests.
DT-6061 User's Manual - Platform (Build 17.1) reports only connections that are associated with instances, and shows the instance ownership of each connection. The list is sorted by local port number. The optional -f flag sorts the list by foreign IP address and port number. The following is a dc app report example: < DT-6061> dc app Active Internet Connections by Applications (sorted by local address): Type Inst FD Local Addr Foreign Addr b2aprt 10 .5 192.168.8.250.1340 192.168.8.15.31000 tn3270 2 .
DT-6061 User's Manual - Platform (Build 17.1) The cpu subcommand reports CPU utilization by process. Processes may be associated with instance numbers as reported by the vfyapp command. Sample Output diag cpu 0: 398711 1: 5014 Interrupts init none onsite none%0 none%1 none%2 none%3 . . .
DT-6061 User's Manual - Platform (Build 17.1) sclk: eth0: SW+0: SW+1: SW+2: sys: app: sched: 0 132 127 0 0 4886 305 407077 0% 0% 0% 0% 0% 1% 0% 99% 113992 8912 4682 5700 2280 Notes: Each line represents a gross category of CPU usage. The numbers in each line are: • total CPU time used (in 100'ths of seconds) since boot (can wrap around) • percentage of available CPU time used since the previous 'diag dev' • the count of events since the last 'diag dev'.
DT-6061 User's Manual - Platform (Build 17.1) 6.8.3.6 TRACE ROUTE - DIAG TRACERT OR DIAG TRTE Syntax: diag tracert diag trte The diag tracert command is the same is the tracert command shown below in section 6.8.7 except this form of the command cannot use the “+n” parameter. 6.8.
DT-6061 User's Manual - Platform (Build 17.1) destination. Each router along the path is required to decrement the TTL on a packet by at least 1 before forwarding it, so the TTL is effectively a hop count. When the TTL on a packet reaches 0, the router is supposed to send back an ICMP Time Exceeded message to the source system.
DT-6061 User's Manual - Platform (Build 17.1) The vfy cfg (or vfycfg) command displays each configured instance, and what application type is configured on that application instance. The parameter is an optional argument to specify the beginning instance number to begin the display. If not specified, it defaults to the number one. The report displays the instance number and application installed on that number.
DT-6061 User's Manual - Platform (Build 17.1) 6.9 HIGH AVAILABILITY OPTION The High Availability option couples two DT-6061 modules as an active and a standby. The active DT-6061 runs applications, while the standby "stands by" and monitors the active DT6061. If the active DT-6061 fails or loses power, the standby will shortly take over the active role. In standby mode, the DT-6061 has completed system boot, but has not started applications.
DT-6061 User's Manual - Platform (Build 17.1) synchronizing, thus disabling the ability to switchover from one to the other. The four and one half minute interval allows the console operator time to investigate what the problem is and take corrective action. 6.9.
DT-6061 User's Manual - Platform (Build 17.1) standby software in sync with the active. The release notes for some platform updates may countermand use of stbyupd os, in which case the normal install procedures should be performed on the standby. Following installation or the alternative stbyupd procedure, the software must be registered on both the standby and the active. 6.9.2.2 OPERATIONAL CONFIGURATION – STBYUPD CFG The assignment of application types to instances, i.e.
DT-6061 User's Manual - Platform (Build 17.1) the active DT-6061. Either way, registration of the application on the standby still needs to be done manually. The SCAN procedure requires quite a bit of overhead on the active DT-6061, so it is recommended to make the SCAN period as long as the user's requirements will tolerate (e.g. 60 minutes). The AGE delay prevents potentially fault-inducing configuration changes from propagating to the standby.
DT-6061 User's Manual - Platform (Build 17.1) snmp switchover timeout timezone The help command at the standby console shows only the commands that ARE allowed. The date command at the standby console may not be used to change the date. As described above, the standby receives the current time from the active. 12/14/09 Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) 7 APPENDIX A: CONSOLE CABLE - SPECIAL WIRING DIAGRAMS Figure 6: Console Cable Pin Assignment 123 4 56 78 Female RJ45 PIN Numbering Figure 7: Special Wiring for Modular Cable Console Cable - SPECIAL WIRING (DT-Products) 1 2 3 4 5 6 7 8 12/14/09 RJ45 RJ45 GND GND CTS CTS RD RD DCD DCD TD TD DTR DTR GND GND RTS RTS Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) 7.1 THE DB9 CONSOLE ADAPTER Some Personal Computers use a 9-pin DB9 interface for serial communications. The terminal emulation programs may require certain lead status. Since console connections are generally implemented as three wire interfaces (i.e. RxD, TxD, and SG); this may pose a problem for the terminal emulation programs. Below is depicted the wiring of a DB9 adapter which eliminates the problems associated with these terminal emulation programs.
DT-6061 User's Manual - Platform (Build 17.1) 8 A P P E N D I X B : S N M P M I B VA R I A B L E D ATA B A S E A N D T R A P S The DT-6XXX SNMP V1 agent supports a multitude of SNMP MIB variables accessible by get and set operations and SNMP trap operations, One or more SNMP managers may query the SNMP agent. Command Operational Result Get Requests the values of one or more Management Information Base (MIB) variables. GetNext Enables MIB variables to be read sequentially, one variable at a time.
DT-6061 User's Manual - Platform (Build 17.1) MIB Variable Name MIB Console Equivalent Access 1.3.6.1.2.1.4.5.0 IpInAddrErrors MIB-II Nbr Rx Packets w/Wrong Addr RO 1.3.6.1.2.1.4.6.0 IpForwDatagrams MIB-II None RO 1.3.6.1.2.1.4.7.0 IpInUnknownProtos MIB-II Nbr of Packets w/Unk Protocol RO 1.3.6.1.2.1.4.8.0 IpInDiscards MIB-II Nbr of Packets Disc due to RO Resource 1.3.6.1.2.1.4.9.0 IpInDelivers MIB-II Inferred from DMEAS counters 1.3.6.1.2.1.4.10.
DT-6061 User's Manual - Platform (Build 17.1) MIB Variable Name MIB Console Equivalent Access 1.3.6.1.2.1.6.9.0 TcpCurrEstab MIB-II None RO 1.3.6.1.2.1.6.10.0 TcpInSegs MIB-II None RO 1.3.6.1.2.1.6.11.0 TcpOutSegs MIB-II None RO 1.3.6.1.2.1.6.12.0 TcpRetransSegs MIB-II None RO 1.3.6.1.2.1.6.13.X TcpConnTable Entries MIB-II None RO 1.3.6.1.2.1.6.14.0 TcpInErrs MIB-II None RO 1.3.6.1.2.1.6.15.0 TcpOutRsts MIB-II None RO 1.3.6.1.2.1.7.1.
DT-6061 User's Manual - Platform (Build 17.1) 9 APPENDIX C: TCP/UDP PORT NUMBERS The DT-6061 uses the following TCP and UDP ports. These ports cannot be changed by configuring them. Protocol Port Number Purpose UDP 161 Used by SNMP managers to set MIB values or get MIB data from the DT-6061 UDP 162 Used by the DT-6061 SNMP agent for sending Traps to the designated SNMP manager TCP 1023 The telnet console port for the platform. Duplicates the input and output of the hard-wired serial console.
DT-6061 User's Manual - Platform (Build 17.1) 1 0 A P P E N D I X D : T H E D I S P L AY MEASUREMENTS (DM) REPORT The DT-6061 platform maintains measurements of network activity as an aggregate of all the application instances. The measurements are grouped into four categories: IP, TCP, UDP, and ICMP. Many of these measurements are related to variables included in MIB II - Management Information Base for Network Management of TCP/IP-based Internets (RFC1213).
DT-6061 User's Manual - Platform (Build 17.1) Measurement descriptions: IP 1: The total number of input datagrams received from interfaces, including those received in error. IP 2: The number of input datagrams discarded due to errors in their IP headers, broken down by bad checksums, version number mismatch, other format errors, time-to-live exceeded, errors discovered in processing their IP options, etc. IP 3: The number of IP fragments received which needed to be reassembled at this entity.
DT-6061 User's Manual - Platform (Build 17.1) 10.
DT-6061 User's Manual - Platform (Build 17.
DT-6061 User's Manual - Platform (Build 17.1) 10.
DT-6061 User's Manual - Platform (Build 17.1) 10.4 ICMP – DM ICMP Note - within the output and input histograms embedded in this report, only parameters with nonzero values will be printed.
DT-6061 User's Manual - Platform (Build 17.1) Measurement descriptions: ICMP 1: The number of ICMP messages which the entity received but determined as having ICMP-specific errors (bad ICMP checksums, bad length, etc.). ICMP 2: The number of ICMP Echo Reply messages sent. ICMP 3: The number of ICMP Destination Unreachable messages sent. ICMP 4: The number of ICMP Source Quench messages sent. ICMP 5: The number of ICMP Redirect messages sent. ICMP 6: The number of ICMP Echo (request) messages sent.
DT-6061 User's Manual - Platform (Build 17.1) 10.5 ETH – DM ETH dm eth Name Mtu Network Address Drop LCL 16384 LCL 16384 127 127.0.0.1 SNP 1500 ETH 1500 00.60.0a.0b.3a.7b ETH 1500 192.168.8 192.168.8.199 ETH 1500 192.168.8.48/ 192.168.8.48 12/14/09 Ipkts Ierrs 2 2 0 8824303 8824303 8824303 Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) 11 APPENDIX E: BRIEF DESCRIPTIONS OF D T- 6 X X X A P P L I C AT I O N S 11.1 IP-BHI The IP-BHI (BiSync Host Interface) application allows a legacy BiSync host to connect to an IP network (using a DT-4000). Each instance of the application emulates one BiSync line with up to 32 cluster controllers and up to 32 logical devices per cluster controller.
DT-6061 User's Manual - Platform (Build 17.1) LoopCare® product. The LoopCare product is the evolution of the Lucent Technologies MLT operations system. The IP-LTCN can replace a DCN in its entirety. This eliminates a maintenance risk since the DCN is manufacturer discontinued, with a consequential shortage of spare parts. A side benefit is that the IP-LTCN will free up the 120 square feet of conditioned floor space taken up by the DCN.
DT-6061 User's Manual - Platform (Build 17.1) maintenance. Finally, the physical location of these printers may not be convenient, due to requirements implied by their legacy interfaces. The IP-SPOOL application provides print spooling per RFC1179 to a shared print resource. It provides the ability to route print output to a shared printer anywhere in the IP network. It reduces the overall cost associated with legacy interfaces by eliminating underutilized, dedicated equipment and its maintenance.
DT-6061 User's Manual - Platform (Build 17.1) 11.12 ONSITE The ONSITE application for the DT-6XXX Network Processor provides a connection and monitoring service for DT-9001 devices. This application translates DT-9001 temperature reports or contact state changes into text-based messages to be delivered to IP-connected host machines. Multiple DT-9001 devices with multiple contacts can be monitored, and multiple hosts may receive messages as result of a single event from a DT-9001.
DT-6061 User's Manual - Platform (Build 17.1) 1 2 A P P E N D I X F : D T- 6 0 6 1 S P E C I F I C AT I O N S Note: Shielded cables must be used in order to maintain compliance with EMC requirements. 12.1 CON (CONSOLE) A standard interface that uses binary data interchange between DTE and DCE. The RS-232C interface uses an RJ45 connector and operates at 9600 bits per second (bps). 12.2 RS-232/V.35 12.2.1 RS-232C A standard interface that uses binary data interchange between DTE and DCE.
DT-6061 User's Manual - Platform (Build 17.1) 12.
DT-6061 User's Manual - Platform (Build 17.1) A representative designated by the supplier should coordinate repairs to certified equipment. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
DT-6061 User's Manual - Platform (Build 17.1) POWER REQUIREMENTS Voltages Current Draw Power Input Requirements DT-6061 Operating Voltage 5V @ 800 mA Nominal Stand-alone AC to 5V DC power supply 115V @ 48mA Nominal 115V @ 90 mA Maximum Stand-alone 48V DC power supply 48V @ 104 mA Nominal 48V @ 195 mA Maximum Rack-mount DC (six units) 48V @ 624 mA Nominal 48V @ 1.17 A Maximum Table 12: Power Requirements 12/14/09 Datatek Applications Inc.
DT-6061 User's Manual - Platform (Build 17.1) 1 3 H A R D WA R E WA R R A N T Y The warranty period for hardware shall be ninety (90) days from the date of shipment from Datatek Applications, Inc. Replacements and repairs are guaranteed for the longer of the remaining original warranty period or 30 days.
DT-6061 User's Manual - Platform (Build 17.1) 14.3 SOFTWARE SUPPORT SOFTWARE support is not provided by Manufacturer, or its affiliates or subsidiaries separate from the HARDWARE. For SOFTWARE support, please contact your supplier of the HARDWARE.
DT-6061 User's Manual - Platform (Build 17.1) 14.7 SPECIAL PROVISIONS The SOFTWARE and documentation are provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and HARDWARE Software clause at DFARS 252.227-7013 or subparagraphs (c)(1) and (2) of the Commercial HARDWARE SoftwareRestricted Rights at 48 CFR 52.227-19, as applicable.