User`s manual

Supplement to DT-6061 User's Manual (Platform) for
IP -LTCN Application
04/23/02
Datatek Applications Inc.
10
3 UPDATED APPLICATION I NSTALLATION
From time to time as needed, new application or DT-6061 platform software is released. The
recommended procedure for installing new application or platform software is to use the install
command on both the active and standby DT-6061. It doesn't matter which DT-6061 is updated
first. However, it is recommended that the installation be performed on the standby system first.
Follow the directions in section 2.2 above to install new application software. After installing on
the standby only, do a switchover to force the standby to become the active. Then run for a
while. That way, if some problem is experienced as the result of using the updated application,
simply switch back to the old active which has the previous build of the application software. After
a sufficient period (the administrator decides the length), if everything is running satisfactorily,
install the updated application on the standby that was previously the active system.
Note that the install process automatically restarts the IP-LTCN application after it completes on
the active system.
Note for installing new platform software, the procedure is very similar. However, separate
instructions will be sent in the release notes that accompany the platform software.
.
4 SWITCHOVER – HIGH AVAILABILITY M ODE
Syntax: switchover
The switchover command, available only at the console of the active DT-6061, forces a
switchover to the standby DT-6061. The former active DT-6061 then reboots itself into standby
mode. (In contrast, if a reboot command is performed at the active console, that simply reboots
the active DT-6061 back to active mode. Note also that when REBOOT is used on an active DT-
6061, the standby allows the active a little extra time to complete so that the standby does not
mistakenly think the active is down and cause a switchover.)
5 DT-6061 COMMANDS NOT AVAILABLE IN S TANDBY HIGH
AVAILABILITY M ODE
The following commands are not allowed at the console of a standby DT-6061 enabled for high-
availability:
app
backup
dtproduct
remove
restart
retrieve
rstapp
stby
switchover
timezone
in an IP only network. All ports support only IP endpoints. See the Datatek web site at
www.datatekcorp.com