Instructions
UM-0085-B09  DT80 Range User Manual  Page 284 
RG 
7.  Disconnect the battery terminals 
(models with internal battery only) 
8.  Remove screws on bottom of logger. DT80/81/82 models have two screws, 
DT85 models have three.  
9.  Remove the battery cage 
(models with internal battery only) 
10. Carefully slide the circuit board bundle partially out of the case. Be careful of 
the flexible cable running between the top circuit board and the keypad. Do 
not completely remove the circuit boards from the case. 
For models with integrated modem, remove the modem module from the 
logger case but leave its cables connected. 
Note: Before touching the circuit boards, discharge any static electricity that may be 
present on your body by touching a grounded metal surface or wearing an anti-static 
wrist strap. 
11. Open the boards slightly so the lithium battery can be removed. 
Figure 116: How to remove the lithium battery 
Warning1: When installing the new lithium battery, observe the correct polarity, as marked on the printed circuit board. 
Warning2: Any replacement battery must be identical in specification to the factory fitted battery. There is a risk of explosion if the 
battery is replaced by an incorrect type. 
Warning3: Dispose of used batteries via an appropriate recycling facility only. 
Warning4: When reconnecting the main battery (if fitted), observe the correct polarity. The red plug connects to the positive (+) battery 
terminal. 
Warning5: When reinserting the main battery, ensure that the battery is oriented so that battery terminals are closest to the upper side 
of the battery. If the battery is inserted upside down then the terminals may contact the case, causing a risk of a short circuit. 