Instructions
UM-0085-B09  DT80 Range User Manual  Page 387 
RG 
HRESET 
generate a hardware reset of the DT80 
  273 
INIT 
clear current job and reset settings to power-on defaults 
  273 
IP 
return DT80 IP address 
  233 
IPGW 
return default gateway IP address 
  233 
IPSN 
return subnet mask 
  233 
LISTD 
option
=
value
option
=
value.. 
return store file details 
  98 
LOCKJOB jobspec 
prevent specified job(s) from being overwritten when a new job is entered 
  63 
LOG "string" 
save a user specified message to the event log 
  276 
LOGOFF 
switch off data/alarm logging for all schedules 
  94 
LOGOFF
sched 
switch off data/alarm logging for schedule sched 
  94 
LOGON 
switch on data/alarm logging for all schedules 
  94 
LOGON
sched 
switch on data/alarm logging for schedule sched 
  94 
MODEM 
sub-command 
low level diagnostics for integrated modem 
  218 
NAMEDCVS 
return current values of all named channel variables 
  69 
NTP 
attempt to set time from NTP server 
  270 
P
n 
return the current value of parameter n 
  260 
P
n=value 
set parameter n to value 
  260 
PASSWORD 
return 1 if a comms interface password is set, otherwise 0 
  186 
PASSWORD="
password
" 
set comms interface password 
  186 
PAUSE 
value 
delay for value ms 
  90 
PH 
return current host RS232 port parameters 
  195 
PH=
baudrate
,
databits
,
parity
,
stopbits
,
flow 
set host RS232 port parameters (all parameters are optional) 
  195 
PING 
hostname 
send echo request to specified host computer 
  221 
PROFILE 
return current settings for all profile keys 
  264 
PROFILE 
section
return current settings for all profile keys in section 
  264 
PROFILE 
section
key
return current value of specified profile key 
  264 
PROFILE section key= 
set specified profile key to default
  264 
PROFILE section= 
set all profile keys in section to defaults 
  264 
PROFILE 
section key
=
keystring
set specified profile key to keystring
  264 
PS 
return current serial sensor port parameters 
  198 
PS=mode,baudrate,databits,parity,stopbits, 
flow 
set serial sensor port parameters (all parameters are optional) 
  198 
Q 
terminate an unload 
  110 
RAINFLOWmaxcyc:rej%:m..nIV 
return a rainflow analysis report 
  79 
REMOVEMEDIA 
stop using a USB memory device so it can be safely removed 
  115 
RENAME 
src dest
rename file/folder src to dest (src may also be an FTP URI) 
  116 
RESET 
(obsolete) same as 
INIT 
  273 
RUNJOB "
jobname
" 
replace current job with specified job 
  62 
RUNJOBONINSERT "
jobname
" 
create ONINSERT.DXC for this 
DT80
 on USB memory device 
  64 
RUNJOBONINSERTALL "jobname" 
create global ONINSERT.DXC on USB memory device 
  64 
Sn=a,b,c,d"units" 
define span #n (all parameters other than a and b are optional) 
  65 
SATTN 
set Attn LED 
  123 
SDI12SEND 
sdi-chan 
"
sdi-cmd
" 
send the specified SDI-12 command 
  343 
SERVICEDATA {filename} 
generate service report; optionally write to specified file 
  277 
SESSION 
command 
communications session diagnostics 
  227 
SETDIALOUTNUMBER "phonenum" 
set the number to call when DIAL command is issued 
  203 
SETMODBUS channels format scaling 
define data formats used when communicating with Modbus client system 
  178 
SHOWPROG 
jobspec 
return the program text for the specified job(s) 
  63 
SIGNOFF 
end authenticated user session (password required to reconnect) 
  259 
SIGNON 
start authenticated user session 
  259 
SINGLEPUSH 
(obsolete) same as 
HRESET 
  273 
SSDIRECT port "terminator" 
forward all subsequent commands, terminated by specified string, to serial 
channel port (1=serial sensor, 2=host RS232) 
  356 
STATUS 
return a status report 
  276 
STATUS
n 
return line n of the status report 
  276 
STATUS14 "jobname" 
return internal details about specified job 
  276 
Tn=a,b,c"units" 
define thermistor scaling function #n (all parameters other than a are 
optional) 
  66 