Setup guide

Dirac Theater Setup Guide Version 1.01
Document # 9301H40300V1.01
4
c. Sequence a noise burst across multiple channels. Declare a first and last channel. The noise
will index from the first channel to the last channel in 3-second increments.
d. Send a NetCmd to the target AP20 and see the returned message displayed in the AP20 Proxy
debug window. Simply type the NetCmd into the Proxy and send it to the AP20.
e. Enable/ Disable and bypass the Dirac Live
®
playback engine in the target AP20. (This is
useful to demonstrate Dirac Live
®
room optimization.)
5. Operating the Get State button (in the AP20 Proxy) will report back whether or not Dirac Live
®
is enabled/ disabled or bypassed. It also will report the name of the filter coefficients that are
currently loaded in the target AP20.
To use the AP20 Proxy as a testing tool you must first operate the Setup ON button to put the
target AP20 into setup mode.
1.4. Starting Dirac Live® Configuration software
1. Start your laptop and run the Dirac AP20 Proxy application (AP20cfg.exe).
2. When the application has started, select the AP20 you will be optimizing from the pulldown list
in the upper left corner.
If the AP20 you want does not appear in the list, select Refresh List.
3. To start a VNC session with the AP20 click on the Remote Session button in the lower left
corner. This optionally allows you to view and control the AP20 front panel menu remotely.
A VNC connection box will appear with the IP Address of the AP20. If the AP20 address does
not appear you may have to use the pulldown and select the correct address. If you don’t know
the address, it may be necessary to find it in the AP20 Network menu.
4. Once you have selected the address, click on Connect.
A VNC authentication box will prompt you to enter a password.
5. In the password box enter a dash (-), then select OK button. If the AP20 has been configured
with a password for the Setup menus, then use that password instead of the dash.
You are now connected directly with the AP20, and the AP20 menu should now be visible on the
laptop screen. You can navigate the menus and control the AP20 remotely.
6. At this time, verify the fader is at “7.0”.
1.5. Set sound levels to establish a baseline
Prior to performing the Dirac Live
®
EQ procedures, it is necessary to first calibrate the speakers in the
auditorium to establish a baseline.
Equipment needed:
Calibrated SPL meter
USB-Pre or equivalent pre-amp
Procedure:
In the auditorium, confirm that all amplifiers are ON, mute is OFF, and masking and curtains
are opened.
Set analog output levels on the AP20 to zero (that is, No ‘gain’ nor ‘cut’).
On the AP20: Format > Output Channel Profile > Analog Output Levels