User manual

<Serial>
Support engineers can configure the serial option to monitor a serial port for a string pattern. As an
example;
<Serial>
<Enable>Yes</Enable>
<Settings>COM1,9600,N,8,1</Settings>
</Serial>
The serial port settings/attributes are also set here and must match those of the device sending the
data. Note: Currently only one serial port can be monitored by the dCine, however you can send
triggers out any available serial ports.
Once the serial port is configured support engineers can define events to listen for, such as a string
pattern like “FireAlarm” coming from another device. See the Events section of this manual for
more information.
Options in the <Serial> section include;
<Enable> : The Enable option allows support engineers to Enable(Yes) or Disable(No)
the monitoring of a serial device.
<Settings> : Support engineers use this option to set which of the serial ports is to be
monitored for string patterns and to configure the attributes for that serial port. The earlier
example sets COM port 1, 9600 baud, no parity, 8 bits , 1 stop bit. This configuration
should typically work when monitoring data coming from an external device.
Copyright©2012 digitAll Pty Ltd 37